Irregular printing
Label feeding is not stable
(skew) when printing
Skip labels when printing
Wrinkle Problem
RTC time is incorrect when
reboot the printer
The printing position of small
label is incorrect
* The printer is in Hex Dump
mode.
* The RS-232 setting is
incorrect.
* The media guides do not
touch the edge of the media.
* Label size is not specified
properly.
* Sensor sensitivity is not set
properly.
* The media sensor is covered
with dust.
* Printhead pressure is
incorrect.
* Ribbon installation is
incorrect.
* Media installation is incorrect.
* Print density is incorrect.
* Media feeding is incorrect.
* The battery has run down.
* Media sensor sensitivity is
not set properly.
* Label size is incorrect.
* The parameter Shift Y is
incorrect.
* The vertical offset setting in
the driver is incorrect.
- 60 -
* Turn off and on the printer to skip the
dump mode.
* Re-set the Rs-232 setting.
* If the label is moving to the right side,
please move the label guide to left.
* If the label is moving to the left side,
please move the label guide to right.
* Check if label size is setup correctly.
* Calibrate the sensor by Auto Gap or
Manual Gap options.
* Clear the GAP/Black mark sensor by
blower.
* Please set the suitable density to have
good print quality.
* Make sure the label guides touch the
edge of the media guide.
* Check if there is a battery on the main
board.
* Calibrate the sensor sensitivity again.
* Set the correct label size and gap size.
* Use DiagTool to fine tune the parameter
of Shift Y.
* If using the software BarTender, please
set the vertical offset in the driver.