General Information

About Generac PWRcell Battery

The Generac PWRcell Battery is the storage component
of the Generac PWRcell system. The Generac PWRcell
Battery
can
be
used
applications, such as self-supply, rate arbitrage and clean
backup power. The Generac PWRcell Battery is
designed to work seamlessly with Generac PV Link
Optimizers and the Generac PWRcell Inverter to form the
Generac PWRcell system for grid-tie solar-plus-storage.
All Generac PWRcell products use the REbus™ 380VDC
nanogrid to connect energy sources, storage and loads.
.
A
Solar Panels
B
Generac PV Link Optimizers
C
Generac PWRcell Battery
D
REbus

Communication

All communication between REbus devices takes place
over the REbus conductors using Power Line Carrier
(PLC) communication. No additional communication
wiring or equipment is required for communication
between a Generac PWRcell Battery, inverter, PV array,
and/or other REbus enabled batteries.

System Operational Modes

The Generac PWRcell system has several operational
modes available for various installation configurations,
markets, and applications. Operational modes are
selected through the Generac PWRcell Inverter control
panel. The inverter prioritizes the distribution of power
differently based on the selected operational mode.
See the Generac PWRcell Inverter installation and
operation
manuals
for
configuring the entire system for each operational mode.
8
for
grid-connected
A
C
D
B
Figure 2-4. Generac PWRcell System Example
complete
instructions
The REbus nanogrid automates the flow of power to
enable plug-and-play setup and operation of Generac
solar
PWRcell equipment.
In
Figure
2-4, a REbus compatible Generac PWRcell
Inverter (E) is directly connected to Generac PV Link
Optimizers (B) and Generac PWRcell Battery (E) on the
DC (REbus) line (D). To the right of the inverter are AC
lines: 240VAC or 208VAC for grid and home loads (G),
and protected load (H) support up to 50A.
E
E
Generac PWRcell Inverter
F
Grid
G
Loads
H
Protected Loads

Inverter Control Panel

See
Figure
2-5. The Generac PWRcell Battery is
controlled through the Generac PWRcell Inverter control
panel. Use the inverter control panel to enable or disable
the battery, and to set the operational mode for the
Generac PWRcell system. See the Generac PWRcell
Inverter Owner's Manual for more information on settings
and display screens.
on
Figure 2-5. Inverter Control Panel
F
G
.
REbus
Inverter
Internet
Shutdown
(hold)
Owner's Manual for Genera PWRcell Battery
H
009893