Maintenance
Abrasive Containment and Disposal
Empty the abrasive hopper by placing a pail 
or plastic bag under either of the hopper 
outlets and open the valve.
Empty the container and repeat as needed.
Warning: Excessive abrasive in the hopper may 
cause powder to leak through vent holes.
Filter Cleaners
Filter cleaning mallets are located on both 
sides of the ProCenter Plus.  Before each 
shift, with the power turned off, pull and 
release the mallets two or three times.  
This action will dislodge spent media that 
may have collected in the HEPA filter.
Changing the HEPA Filter
Remove any equipment sitting 
on top of the filter box.  
Disconnect the power cords 
on both sides of the filter box.  
Remove filter box cover.  
Remove and replace filter. 
(CTR280‐1 Replacement HEPA 
filter assembly)
Air Dryer Maintenance
The desiccant inside the air dryer bowl will gradually turn from bright 
orange to dark green as it becomes saturated.  Change according to 
the instructions included with the 
air dryer.
For maintenance instructions on your 
air dryer, please see manual "AD5100 
Series – Desiccant Air Dryer."
ProCenter Plus
Manual
NEED HELP?
Comco Tech Support: 818‐841‐5500
Tech@comcoinc.com
8/2021
www.comcoinc.com
TS414

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProCenter Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Comco ProCenter Plus

  • Page 1 Empty the container and repeat as needed. Warning: Excessive abrasive in the hopper may  cause powder to leak through vent holes. Filter Cleaners Filter cleaning mallets are located on both  sides of the ProCenter Plus.  Before each  shift, with the power turned off, pull and  release the mallets two or three times.   This action will dislodge spent media that  may have collected in the HEPA filter. Changing the HEPA Filter Remove any equipment sitting  on top of the filter box.   Disconnect the power cords  on both sides of the filter box.   Remove filter box cover.   Remove and replace filter.  (CTR280‐1 Replacement HEPA  filter assembly) Air Dryer Maintenance The desiccant inside the air dryer bowl will gradually turn from bright  orange to dark green as it becomes saturated.  Change according to  the instructions included with the  air dryer. NEED HELP? Comco Tech Support: 818‐841‐5500 For maintenance instructions on your  Tech@comcoinc.com www.comcoinc.com air dryer, please see manual “AD5100  Series – Desiccant Air Dryer.” 8/2021 TS414...
  • Page 2 HAND‐ used for operating other  PIECE  equipment. HOSE Air Pressure Regulators BLASTER POWER  There are two air regulator controls on the  CORD electronics box located on back of the unit. POWER  • Air Purge: regulates flow to the air jets;  CORD VENT  prevents abrasive from accumulating in  HOSE front of the work chamber. Note: There should always be air flowing out of the air jets SHOP  • Blow‐Off: sets air pressure on the blow‐off  AIR  FROM  DRYER The air pressure regulators are preset at the  Before you set up and  operate your Comco  TO AIR  factory for reasonable air flow and should  blaster, read and follow  DRYER not require adjustment with the demands  the safety instructions in  of normal production. your Maintenance Manual.