Electro-Voice Xi Series Xi-2181A Supplementary Manual
Electro-Voice Xi Series Xi-2181A Supplementary Manual

Electro-Voice Xi Series Xi-2181A Supplementary Manual

Electrovoice xi series xi-2181a: supplementary guide
Hide thumbs Also See for Xi Series Xi-2181A:

Advertisement

Xi-Series Loudspeakers

EV Dx38 Digital Parameters

Loudspeaker System Xi-2181A
Un-hide cells for revision history Use Low Frequency boost sparingly.
and specific system notes. Adjust Delay and Output Level as needed.
Programmer: 1st Rev. - Last Rev. Steve Jakowski 03JUN04
Frequency Band
Connector
Input Source Routing
Filter 1 Type
Filter 1 Freq.
Filter 1 Q/Slope
(Q,dB/Oct)
Filter 1 Level
Filter 2 Type
Filter 2 Freq.
Filter 2 Q/Slope
(Q,dB/Oct)
Filter 2 Level
Filter 3 Type
Filter 3 Freq.
Filter 3 Q/Slope
(Q,dB/Oct)
Filter 3 Level
Filter 4 Type
Filter 4 Freq.
Filter 4 Q/Slope
(Q,dB/Oct)
Filter 4 Level
Filter 5 Type
Filter 5 Freq.
Filter 5 Q/Slope
(Q,dB/Oct)
Filter 1 Level
HP Resp
(Type,dB/Oct)
HP Frequency (Hz)
HP Polarity (Norm/Inv)
LP Resp
(Type,dB/Oct)
LP Frequency (Hz)
LP Polarity (Norm/Inv)
Input Delays
1+2 Input Delay
Output Delay
Output Delay Unit
Comp Thresh
Comp Ratio
Comp Attack
Comp Release
Limit Thresh
Limiter
Limit Release
Level (dB)
Output
Polarity (Norm/Inv)
Knobs
Output
Notes Xover point may be adjusted as needed up to 160 Hz.
Room or Voicing EQ must be done with Input EQ only.
FR
FR
SUB
IN 1
IN 2
OUT 1 OUT 2 OUT 3 OUT 4
IN 1
PEQ
68
(Hz)
3.5
-2
(dB)
PEQ
108
(Hz)
3.5
-2
(dB)
PEQ
132
(Hz)
3.5
+2
(dB)
LoPass
220
(Hz)
12dB
Q:0.7
(dB)
(Hz)
(dB)
BW24
35
NORM
LR24
80-160
NORM
1.9
1.9
(mSec)
1.9
(mSec)
As
Needed
(dBu)
(X:1)
(mSec)
(mSec)
+2
(dBu)
100
(mSec)
As
Needed
Input
0
0
-6
Page 1 of
Dx38 OS Rev.: 0.90
FR
IN 1
0
-6
-6
-6
Rev. 2.0 10/24/2000
FR
IN 2
OUT 1 OUT 2 OUT 3 OUT 4
0
-6
-6
-6
File: Dx38 Form
-6

Advertisement