Manage Analog Input (4Ch Signal End) - Asus AAEON SRG-ADIO User Manual

Iot gatewey system
Table of Contents

Advertisement

3.7.4.3

Manage Analog Input (4CH Signal End)

Enter the following command to view status for all channels:
$ rd_exadc -a
Config-CH# for each channel use the following numerical inputs:
0
Voltage
1
Current
-1
Disable (no value will be returned)
For example: The following command will return voltage values for all four
channels:
$ rd_exadc -a
The system will output information based on the inputs you used, as follows:
To view status for a specific channel, use the following command:
$ rd_exadc -c
CHANNEL
MODE
enter 0 for voltage, or 1 for current
Chapter 3 – Gateway Setup and Configuration
Config-CH0
Config-CH1
0
0
0
0
CHANNEL
-M
MODE
is the channel you wish to check, 0, 1, 2, or 3
Config-CH2
Config-CH3
40