Download Print this page

Board Functions - Blue Point Engineering Wizard - VIII Instruction

Advertisement

Board Functions

Page 2
:
DIGITAL - On / Off -Button
Pressing the Digital button will activate the relay output as ON or OFF.
This is a momentary switch. ( Relay - Green LED will turn ON when Digital button is pressed )
GO / RECORD - Button
Replays a set of recorded relay, sound actions.
Starts and Stops the record mode ( Red LED will turn ON indicating recording )
A switch, sensor may be connected to the REM connection and this will function in the same way as the GO
Button
Press and release the GO button to start recording a routine. Press and release the Go - button to stop
recording. If the GO - button is held down and the PLAY slide switch is set to REC, when power is first
applied to the board, all relay memory will be erased. (Takes approximately 20 seconds).
PLAY / REC - Slide Switch
Selects either Playback or Record Mode.
SOUND / RELAY - Slide Switch
Selects either Sound or Relay Mode.
SYNC Terminal
Synchronizing connection for multiple board module operation. On-board terminal connection delivers a pulse
low signal (30 msec) at the start of playback and record event which may be used to trigger other Wizard
boards connected in a chain or master module - slave module setup. Sync output to Rem input of other boards.
REM Terminal
Used to trigger Wizard board by remote switch, sensor. Can also be jumped together for no-stop playback.
LOOP - SINGLE Jumper
To make the Wizard - VIII board play the recorded moves repeatedly, move the Jumper Block to the Loop
position. The recorded moves will start to play when the GO button is first pressed. There will be a pause at
the end of playing (determine by the position of the Delay control) after which the recorded action will start
again. In Single mode, playback will start once and wait for next GO or Sensor input to start.
DELAY - potentiometer.
Pause between playback loop option.
When the Wizard - VIII board is set to the LOOP position, the length of the pause between repeated
playbacks may be set by rotating the on-board Delay control potentiometer.
Turn the Delay control counter clockwise (CCW) for the minimum delay (approximately 2 seconds and
clockwise for the maximum delay (approximately 65 seconds).
AUTO / ON - slide switch.
To make the Wizard - VIII board play the recorded moves repeatedly on power - ON or reset, move the switch
to the "ON" position. The recorded actions will start to play on any power-up.
Clearing Relay Memory to start a new program.
The PLAY / RECORD slide switch must be in the "REC" position.
The GO - button is held down during Power Up, and released after power is applied.
After the initial 20 seconds the board is now ready for new programming.
Clearing Sound Memory to start a new program.
The Audio recording chip cannot be bulk - erased. The audio track can only be replaced by re-recording a new
audio track over the old track or by recording a blank audio session.
NOTE:
The sound chip will not play any sound unless there is a stored relay / digital recording.
If you erase the relay digital recording then the sound chip will not play sound until you have
re-recorded a relay / digital program routine.