Advertisement

Quick Links

Notice to Installer: Instructions must remain with installation.
Product information presented
here re fl
e
s t c
o c
d n
o i t i
s n
a
t t
m i
e
of publication. Consult factory
e r
a g
i d r
g n
d
c s i
e r
a p
c n
s e i
r o
n i
o c
s n
t s i
n e
e i c
. s
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs in the cover
nor the motor housing.
2. Carefully read the literature
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle or control box
must be installed in accordance with the governing codes. Never remove ground pin
from plug.
2. Make certain that the receptacle or control box is within reach of the pump's power
supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that are too long
a safety hazard if the insulation were to become damaged or the connection end were
to fall into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit breakers
of proper capacity. A separate branch circuit is recommended, sized according to the
governing electrical codes for the current shown on the pump name plate.
4. Testing for ground. As a safety measure, each electrical outlet should be checked
for ground using a circuit analyzer which will indicate if the power, neutral and ground
electrician.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. If pump is wired direct, de-energize the circuit at the
control box. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND
PIN. Wear insulated protective shoes and do not stand in water. Pumps equipped
with a grounded plug are designed to help protect against electrical shock. A properly
grounded receptacle or control box must be installed in accordance with governing
codes.
6. Installation and servicing of the pump's electrical circuits and hardware should only be
7. Installation and maintenance of this appliance is not intended for persons (including
children) with reduced physical, sensory or mental capabilities, or lack of experience
or knowledge, unless they have been given supervision or instruction concerning use
of the appliance by a person responsible for their safety.
8. Risk of electrical shock. Do not remove power supply cord and strain relief or connect
conduit directly to the pump. If the supply cable is damaged, it must be replaced by an
authorized Zoeller Representative.
9. Pump may contain oil which becomes pressurized and hot when operating. Allow 2-1/2
hours after disconnecting before attempting service.
10. Pump is not intended for potable water due to possible contamination by oil contained
in the pump.
11. Risk of electrical shock. These pumps have not been investigated for use in swimming
pools and marine areas.
DO NOT USE FOR PUMPING OILS, GASOLINE OR ANY PETROLEUM BY-PRODUCTS.
INSTALLATION INSTRUCTIONS
2802 / 2812 / 2833 / 2835 / 2837
© Copyright 2018 Zoeller Co. All rights reserved.
These materials should be retained for future reference.
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the manual
look for one of the following signal words and be alert to
the potential for personal injury or property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
Warns of electrical shock hazards that CAN cause serious
personal injury, death or major property damage.
Identifies any terminal which is intended for connection
to an external conductor for protection against electrical
shock in case of a fault, or the terminal of a protective
earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR
TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO WARRANTY ON PAGE 2.
®
- 1 -
ZT0313_ECa
60 Hz
Visit our web site:
www.zoellerpumps.com
P/N 094539
0818
Supersedes
0718

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2802 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zoeller 2802

  • Page 1 INSTALLATION INSTRUCTIONS 2802 / 2812 / 2833 / 2835 / 2837 PREINSTALLATION CHECKLIST - ALL INSTALLATIONS 1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs in the cover nor the motor housing.
  • Page 2: Limited Warranty

    “on” or “off” position. Repair and service should be performed by an authorized Zoeller Company Representative only. The installation of variable level float switches is the responsibility of the...
  • Page 3: Service Checklist

    Installation and checking of electrical circuits and hardware should be performed Every 5 years or 10,000 hours of operation: • Remove pump, inspect and service using a Zoeller rebuild kit. Pump is never to be lifted by power cord. • Flush and clean basin.
  • Page 4: Installation Sketches

    10 CM (4") OF GRAVEL SK3108 piping, valves, etc. Float hangers are available from Zoeller Company on All installations must comply with all applicable electrical and plumbing codes.
  • Page 5: Single Phase Wiring Diagram

    SINGLE PHASE WIRING DIAGRAM Model 2802 Model 2812 Model No. Start Capacitor Run Capacitor 400 µF 90 µF 2802 2812 250 VAC 250 VAC ® © Copyright 2018 Zoeller Co. All rights reserved. - 5 -...
  • Page 6 安裝前務必詳讀說明書 60 Hz 文件僅供參考 若有任何修改 Visit our web site: 恕不另行通知 zoellerpumps.com 安 裝 說 明 書 2802 / 2812 / 2833 / 2835 / 2837 安 裝 前 檢 查 1. 安裝前請仔細檢查所有零件。產品如果在運送中受損,請儘速聯絡經銷商。 2. 安裝前仔細閱讀所有提供的文件,熟悉安裝細節,並保存資料以供未來參考。 安全守則 警 告 為防範使用者觸電,本公司所有產品皆配有包含接地功 為避免嚴重或致命的人身傷害及重大財產損失,請閱讀並 能的電線及三插插頭。為確保安全,請勿將插頭的接地...
  • Page 7 損壞、利潤損失、等..。 (1)未依照說明書安裝、操作或維護所造成的故障或損壞。 本公司的責任不超過產品的實售價格。 (2)不當操作、意外或疏忽所造成故障或損壞。 上述為本產品唯一的保固說明,任何人的修改或另做承諾 (3)加裝不屬於本產品的零、配件。 皆為無效。 (4)未依照當地法規進行安裝所造成的危害。 在因涉嫌產品故障而招致損害的情況下, 財產擁有人必須保留該產品以供調查之用。 安裝注意事項 請務必閱讀本裝置之所有安裝資料。 切勿使用本裝置抽取汽油或其他危險液體。 請務必檢查裝置是否在運送中產生可見的損壞。若裝置 請務必在安裝後立即測試水泵,以確認系統正常運作。 顯示受損,請洽經銷商。 請務必詳閱所有適用當地及國家規則,確認安裝符合各 請務必清除水坑中之雜物。將水泵放置在堅固地面上。 項規定。 切勿將水泵放置在泥沙上。 若有疑問,請務必洽製造商查明。 請務必確認水坑大小足以允許浮子自由活動。 請務必考慮電池備用系統,以防停電或故障造成的財產 處理前切斷水泵電源。連結到獨立受保護的接地漏電電 損失。 流斷路器。請勿切斷、拼接或損壞電源線。請勿用電源 請務必每3個月檢查一次系統是否正常運作。 線拉動或舉起水泵。請勿使用延長線。 請務必在出水管線安裝止回閥和管接頭。切勿使用小於 出水口徑尺寸的水管安裝。 ® © 版權所有 : 2018 Zoeller 公司。翻印必究。 - 7 -...
  • Page 8 去除浮子周圍的雜物。 水泵不停止。 浮子開關故障。 聯絡經銷商。 清理進水口附近區域。 進水口周圍有雜物。 排放管堵塞。 必要時卸除排放管,沖走雜物。 由合格電氣技師檢查家庭管線。 電壓太低或不當電壓。 水泵運轉正常,但抽 葉輪受損。 聯絡經銷商。 不到水或水流量太少 。 馬達運轉不當、電容器瑕疵、入水含空氣或造成空 聯絡經銷商。 氣進入水機室。 確保排放管中的通氣孔暢通。 水泵氣鎖。 安裝揚程超過系統設計的揚程。 更換排放管或聯絡經銷商。 揚程或流量使用一般 管路或止回閥阻塞。磨蝕性物質及有害的化學物質 檢查管路、打開並檢查水機。 時間後降低。 造成葉輪及水機損壞。 如果檢查後仍無法排除問題,請與 公司授權的經銷商連絡,切勿自行拆卸水泵。 卓勒 ® © 版權所有 : 2018 Zoeller 公司。翻印必究。 - 8 -...
  • Page 9 泵出口以下。 對浮子的正常運作,通氣孔的位置請避免面向浮子。建議 應使用氣密密封圈隔絕氣體與氣味。 鑽孔位置低於”停止”水位,建議向下 45 度角可降低水流 利用通氣管將氣體與氣味排出。 撞擊桶子產生的噪音。註:該孔需低於水槽蓋板,並需定 期清理,水泵運轉時可看見該小孔有水流出。 用束帶將電源線在出水管上固定牢靠,並使其避開浮子開 關機構。 安裝示意圖 鋼蓋板水池上標準浮子安裝桿 維修蓋 標準管路法蘭 PVC管或輕質不鏽鋼管 小礫石 SK1217 3/16" DIA. 100 mm 某些安裝場合可能需要利用獨立的浮子桿安裝各控 礫石層 SK3108 制開關,以免牽掛到水泵、管路、閥門等。卓勒提 供各種浮子桿,請參考FM0526型錄;也可利用標準 所有安裝作業必須符合適用的水電規範,至少包括現行電工規則 管材與配件製作。 、當地、區域及/或現行配管規則等。不適用於危險性場所。 ® © 版權所有 : 2018 Zoeller 公司。翻印必究。 - 9 -...
  • Page 10 綠色 啟動電容 紅色 橘色 運轉電容 黑色 紅色 白色 橘色 啟動線繞組 熱保護器 主線繞組 啟動線繞組 馬達 主線繞組 主線繞組 馬達 型號 啟動電容 運轉電容 400 µF 90 µF 2802 2812 250 VAC 250 VAC ® © 版權所有 : 2018 Zoeller 公司。翻印必究。 - 10 -...
  • Page 11 #10 金屬螺絲 x 1/2" 控制箱 12" 警 告 電源 L1 L2 白 斷路器 藍 色 色 藍色 (白色) 黑 棕 色 藍色 色 (白色) (綠色) 綠黃色 在控制背板鑽洞3 mm 以安裝斷路器支架。 單相水泵 電源線 這是原始安裝說明的翻譯資料。 ® © 版權所有 : 2018 Zoeller 公司。翻印必究。 - 11 -...

This manual is also suitable for:

2812283328352837

Table of Contents