Test Certificate; Operation; Dimensions; Flow Diagram - Hans Grohe MyFox 13165000 Manual

Table of Contents

Advertisement

Operation (see page 12)
Dimensions (see page 14)

Flow diagram

(see page 14)
Shower outlet
Tub outlet
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not possible
Shower or spout dripping
English
Cause
- Supply pressure inadequate
- Filters are dirty (#97367000)
- Shower filter seal dirty
- Backflow preventers dirty or leaking - Clean backflow preventers, ex-
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Dirt or sedimentation on valve seat,
shut-off unit damaged
Assembly (See Page 6)
Spare parts (see page 15)
Cleaning (see page 16)
Test certificate (see page 11)
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
(#97367000)
- Clean filter seal between shower
and hose
change if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean or exchange shut-off unit
3 (16)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Myfox 1316400083620058351037

Table of Contents