12.3 Automatic Operation

Automatic operation can be set using remote control.
This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature.
After judged the temperature, the operation mode is determined by referring to the below standard.
Then, the unit starts to operate at determined operation mode, until it is switched off using remote control, with
the setting temperature as shown in table below.
The setting temperature for all the operations can be changed one level up or one level down from the standard
temperature as shown in table below by pressing the temperature up or temperature down button at remote
control.
The operation mode judging temperature and standard setting temperature can be increased by 2°C
permanently, by open the circuit of JX03 at indoor unit's printed circuit board.
Intake Air
Temperature
Intake Air
Temperature
Cooling Operation
Soft Dry Operation
Higher
Standard
Lower
Cooling Operation
25°C
Soft Dry Operation
Cooling Operation
23°C
Soft Dry Operation
Setting Temperature (Standard)
25°C
22°C
Cooling
Soft Dry
+2°C
27°C
24°C
±0°C
25°C
22°C
-2°C
23°C
20°C
Cooling Operation
Soft Dry Operation
49
Setting Temperature (Standard)
27°C
24°C