Construction And Water/Refrigeration Circuit Diagram; Kmh Construction; Water-Cooled Models (Swj3) - Hoshizaki KMH-2100SWJ3 Service Manual

Stackable crescent cuber
Hide thumbs Also See for KMH-2100SWJ3:
Table of Contents

Advertisement

I. Construction and Water/Refrigeration Circuit Diagram
A. KMH Construction

1. Water-Cooled Models (SWJ3)

Evaporator Assembly
Cleaning Valve
Check Valve
(water)
Water Pump
Float Switch
Low-Side Service Valve
Thermostatic
Expansion Valves
Check Valves
Hot Gas
Valve
High-Side Service Valve
Spray Tubes
Bin Control Thermostat
Liquid Line
Valve
Strainer
Inlet Water Valve
Control Box
Control Switch
Compressor
7
Junction Boxes
Water Supply Inlet
Main Transformer Box
(3 phase models)
Water Regulating
Valve
High-Pressure Switch
Condenser
Drier

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kmh-2100srjKmh-2100srj3

Table of Contents