Getting Start With Smart Entrance Counter Solution - Jorjin MM5D91E0B User Manual

Entrance counter evaluation kit
Table of Contents

Advertisement

3.3. Getting Start with Smart Entrance Counter Solution

User can set or get the configuration of the radar at the Counter event tab page. Currently
setting items are available:
Sensor Position : Depending on the location of installation, select either ceiling or side.
Ceiling Height: The height at which the module is mounted. The maximum height is 3m.
Min Person Height: The height limit of the person. The maximum height is 2m.
Entrance Width: The width of the passage or the entrance. The maximum width is 3m.
Traffic Light Zone: The detection zone of the smart entrance counter solution.
Sensitivity: Changing the sensitivity changes the threshold for triggering the count. At
higher senility, the threshold is closer to the noise floor.
Sensor Orientation: The sensor can be mounted either in the portrait mode or in
landscape orientation. The figure below describes the definition of longer and shorter
edge.
Counting: To set the direction of in / out
©