3.3. Getting Start with Smart Entrance Counter Solution
User can set or get the configuration of the radar at the Counter event tab page. Currently
setting items are available:
⚫
Sensor Position : Depending on the location of installation, select either ceiling or side.
⚫
Ceiling Height: The height at which the module is mounted. The maximum height is 3m.
⚫
Min Person Height: The height limit of the person. The maximum height is 2m.
⚫
Entrance Width: The width of the passage or the entrance. The maximum width is 3m.
⚫
Traffic Light Zone: The detection zone of the smart entrance counter solution.
⚫
Sensitivity: Changing the sensitivity changes the threshold for triggering the count. At
higher senility, the threshold is closer to the noise floor.
⚫
Sensor Orientation: The sensor can be mounted either in the portrait mode or in
landscape orientation. The figure below describes the definition of longer and shorter
edge.
⚫
Counting: To set the direction of in / out
©
Copyright
JORJIN TECHNOLOGIES INC. 2020
http://www.jorjin.com.tw
CONFIDENTIAL
Doc No: MM5D91E0B-UG-D01
Page 11