VIDEO CALIBRATION

1.4
1.4.1 YPbPr Calibration for TV display format
IFC130
Service Menu
Return
(
Video
Sound
Misc
PW218 1st page
PW218 2nd page
SAA7117AE
PW2300
- Connect Y, Pb, Pr signal to BV600 ("Video Components Enter") with the following standard.
Signal
Y: Sync to teak white
Pr:Sync to teak white
Pb:Sync to teak white
- Exit temporary from Service Mode and select the "Video Components Enter" (press the magenta key on the
RCU "Text" to come back at the service mode )
- Video pattern to calibrate
Calibration Pattern Color bar with no Gamma correction
Picture
Format
- Select "YPbPr Calibration" in the "PW218 1st page" Menu of the Service Mode and press the OK key on
the RCU.
The screen is flashing few minutes and stable after few seconds.
Return
Panel Selection
Analog RGB Calibration
YCbCr Calibration
Factory Reset
BL1.41
BW Expand
CUEC / ICP
FRMEC
...
Flestone Correction
...
...
Film Mode
...
3:2 Film Sensitivity
...
2:2 Film sensitivity
...
Pixel Boost
...
DCS
DCTI
Peaking
Spatial noise Filter
LumaTemp.Noise Filter
LAI
Valeur (Vp-p)
0.7
0.7
0.7
720p60Hz, 2H, 16:9
12
009
000
001
001
000
000
000
004
000
000
000
001
000
064
000