ATS GDS-25 Installation, Operation And Maintenance Manual

ATS GDS-25 Installation, Operation And Maintenance Manual

Ultraviolet disinfection system

Advertisement

Quick Links

Ultraviolet Disinfection Systems
MODEL:
GDS-25
Installation, Operation and
Maintenance Manual
CAUTION: Read and Follow all safety rules and
operating instructions before first use of product.
Dealer Info:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GDS-25 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATS GDS-25

  • Page 1 Ultraviolet Disinfection Systems MODEL: GDS-25 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules and operating instructions before first use of product. Dealer Info:...
  • Page 2 GDS Series ©2016...
  • Page 3: Table Of Contents

    Table of Contents Installation Instructions: General Safety Instructions ................4 Function / Description ..................5 Installation ......................6 Installation Diagram ..................7 Electronic Controls & Startup Procedures ............8 Sample Screen Shots: ....................9 Sanitation Procedure: ....................10 - 11 Maintenance: ........................
  • Page 4: General Safety Instructions

    General Safety Instructions WARNING - to guard against injury, basic safety 1. SAVE THESE INSTRUCTIONS. precautions should be observed, including the 2. WARNING: The ultraviolet light given off by this unit following: can cause serious burns to unprotected eyes and skin. Never look directly at a lit U.V.
  • Page 5: Function / Description

    Model ATS series have a number code designation correspondent to the maximum GPM (gallons per minute) flow rate of the unit. I.E,- GDS-25 has a maximum flow capacity of 25 GPM. Applications: GDS Units are designed to destroy micro-organisms in water supplies. The Ultraviolet lamp peak radiation of 254 nanometer wavelength (nm) destroys or inactivates the D.N.A.
  • Page 6: Installation

    1. When installing the equipment, it is necessary that the Inlets and outlets on GDS-25 units are 1.5” FNPT. Use unit be isolated from vibration, heavy equipment, and Teflon tape on all threaded connections and avoid over poorly connected piping.
  • Page 7: Installation Diagram

    Installation Diagram GDS ©2019 • www.aquat.com GDS Series ©2016...
  • Page 8: Electronic Controls & Startup Procedures

    Electronic Controls & Startup Procedures before the lamp has to be replaced. OPERATING INSTRUCTIONS • DAY LED (Orange)- Number of days remaining before Your U.V. System is equipped to provide a continuous the lamp has to be replaced. monitoring system of the U.V. lamp operational status. This is also equipped with an internal and external fused surge •...
  • Page 9: Sample Screen Shots

    Sample Screen Shots Fig. 2 Fig. 1 Fig. 4 Fig. 3 GDS ©2019 • www.aquat.com GDS Series ©2016...
  • Page 10: Sanitation Procedure

    Sanitation Procedure HOW TO DISINFECT A WATER SYSTEM: continue to run pump if water doesn’t flow. Every new well, or existing water supply system that B. The high level of chlorine required to sanitize has been disrupted for service or repair, should be a water system is corrosive to most metals and disinfected before it is returned to use.
  • Page 11 Sanitation Procedure TABLE 2 ** TOO MUCH CHLORINE IS BETTER THAN TOO LITTLE: NOTE: In situations where it is inconvenient to determine depth Pellets Weight = 1.14 gram each, 25 pellets/oz., 400 pellets/lb. of water or diameter of a drilled well, a minimum of 1/2 gallon of household bleach may be used for wells up to 1 cup of pellets = 1/2 lb., or 200 pellets, or 8 oz.
  • Page 12: Maintenance

    Maintenance QUARTZ SLEEVE: to prevent breakage. Make certain that all finger prints are wiped clean before reinstalling (see installation of the quartz Installation of the Quartz Sleeve: sleeve). Replace o-ring [ATS8-544(1)] every time a quartz sleeve is cleaned or replaced. We reccommend replacing the Always handle quartz sleeves carefully to prevent breaking quartz sleeve once a year.
  • Page 13: Unit Parts Breakdown

    Parts Breakdown - GDS-25 GDS ©2019 • www.aquat.com GDS Series ©2016...
  • Page 14: Circuit Board Layout

    Circuit Board Layout GDS ©2019 • www.aquat.com GDS Series ©2016...
  • Page 15: Wiring Diagram

    Wiring Diagram GDS ©2019 • www.aquat.com GDS Series ©2016...
  • Page 16: Troubleshooting

    Troubleshooting PROBLEM CAUSE CORRECTION U.V. lamp will not light Check input voltage if below Install a voltage regulator or above 120 volts Electrical cord disconnected Check, replace or outlet defective Defective U.V. lamp Replace Lamp Defective lamp ballast Check output voltage Replace ballast Loose open-circuit wire Trace out and repair...
  • Page 17: Sterile Water Sample Precedures

    Sterile Water Sample Procedures SUGGESTED PROCEDURE FOR OBTAINING STERILE WATER SAMPLES: Prior to taking the water sample, be sure to have on hand an adequate supply of sterile bottles (as shown in Fig 1). These sterile bottles should be obtained from a reputable laboratory and should have been autoclaved and contained within a plastic outer wrapping.
  • Page 18: Specifications

    GDS-25 Specifications GDS ©2019 • www.aquat.com GDS Series ©2016...
  • Page 19: Notes

    Notes GDS Series ©2016 GDS ©2019 • www.aquat.com...
  • Page 20: Warranty

    Warranty GDS ©2019 • www.aquat.com GDS Series ©2016...

Table of Contents