MTS CIRCUIT ADJUSTMENT
(HI-FI MODELS ONLY)

5-4 ADJUSTMENT OF SIF-INPUT LEVEL

Measuring
AC milli-voltmeter and RF signal
instrument
generator.
Mode
E-E
Input signal
RF CH-10 (at 300Hz 30% MOD.)
Test point
AUDIO OUT jack (R channel)
Control
R142(S-IF ADJ.)
Specification
Right CH Output Minimum
1. Feed the RF signal CH-10 (at 300Hz 30% MOD.) to
antenna terminal.
2. Connect the AC milli-voltmeter to right channel output
terminal.
3. Set the audio signal to 300Hz and the modulation facter
to 30% (Left channel only) and adjust R142 (S-IF ADJ.)
so that the right channel output becomes minimized.

5-5 ADJUSTMENT OF STEREO SEPARATION

Measuring
AC milli-voltmeter and RF signal
instrument
generator.
Mode
E-E
Input signal
RF CH-10 (at 3kHz 30% MOD.)
Test point
AUDIO OUT jack (R channel)
Control
R144 (SEPARATION ADJ.)
Specification
Right CH Output Minimum
1. Feed the RF signal CH-10 (at 3kHz 30% MOD.) to
antenna terminal.
2. Connect the AC milli-voltmeter to right channel output
terminal.
3. Set the audio signal to 3kHz and the modulation factor
to 30% (Left channel only) and adjust R144 (SEPARA-
TION ADJ.) so that the right channel output becomes
minimized.
4. Repeat step 5-4 ADJUSTMENT OF SIF-INPUT LEVEL,
until obtain a specification.