Installation
Figure 10: Connecting the System Ground for CGP-OLT-16T
1
Step 2
Prepare the other end of the grounding wire with a ring lug, and secure it to the rack with a screw.
Connecting to the Power Source
Each power cable is shipped with mating connectors, with one of the connectors on the power socket and the
other connector on the front panel of the power supply. The steps to install the AC-input and DC-input power
supplies is the same, but you must ground them as explained below:
• AC-input power supply: The device is automatically grounded when you connect its power cable to the
• DC-input power supply: You must not connect the power supply directly to the earth ground.
Use one power cord for each power supply to connect the power supply to its power source.
Connecting to an AC Power Source
Warning
Take care when connecting units to the supply circuit so that wiring is not overloaded. Statement 1018
Before you begin
Prior to connecting the power supply to a power source, ensure that the chassis is properly grounded.
Procedure
Step 1
Plug the power cable into the power connector on the power supply unit of the OLT.
1xM4 screw
power supply and the power source.
2
Grounding wire with grounding lug
Cisco Catalyst PON Series Switches Hardware Installation Guide
Connecting to the Power Source
23