10-Installation
10-11
10-12
Note: Aqua-stop-system:
Some models are equipped with an aqua-stop inlet hose (B).The aqua-stop system
protects against water damage by automatically cutting the fresh water supply in case
of a leaking hose. This is indicated by a red marker (C). The hose must be replaced.
10-13
WARNING!
dry and leack free!
Take care these parts are never to be crushed, kinked, or twisted
If the supply cord is damaged, it must be replaced by the service agent (see warranty
card) in order to avoid a hazard. .
Note: Hygiene
nance run programme HYGIENE with no load and small amount of detergent in wash-
ing agent compartment (2) or with special machine cleaner to remove possibly corrup-
tive residues.
28
10.7 Fresh Water Connection
Make sure that the gaskets are inserted.
1. Connect the water inlet hose with the angled end
to the appliance (Fig. 10-11). Tighten the screw
joint by hand.
2. The other end connect to a water tap with a 3/4"
thread (Fig. 10-12).
10.8 Electrical Connection
Before each connection check if:
power supply, socket and fusing are appropriate to
the rating plate.
the power socket is earthed and no multi-plug or
extension are used.
the power plug and socket are strictly according.
Put the plug into the socket (Fig. 10-13).