Fujitsu PRIMERGY RX2520 M5 Operating Manual page 34

Hide thumbs Also See for PRIMERGY RX2520 M5:
Table of Contents

Advertisement

Product description
Pos. Label
I
Note on CSS and Global Error indicators on the I/O panel:
If CSS and Global Error indicators are located in the same place on the
I/O panel of the server, also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
I
For more information on detected errors, see the System Event Log or
use the ServerView Operations Manager or iRMC web interface.
iRMC-related status signals
Global error
ID indicator
indicator
flashing blue
off
flashing blue
flashing orange
34
Indicator
Status
off
Global
orange on
Error
indicator,
see also
"iRMC-
related
flashing
status
orange
signals" on
page 34
Description
A remote connection has been
established. Local VGA output has been
disabled during the remote session.
An emergency flash of the iRMC firmware
is in progress.
I
Operating Manual
Description
No critical event detected (non
CSS
component).
Prefailure event detected (non
CSS
component).
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
range
– Defective sensor
– CPU error
– Error detected by server
management software
For more information on the
emergency flash of the iRMC
firmware, see the "FUJITSU Server
PRIMERGY RX2520 M5 Upgrade
and Maintenance Manual".