7. MAINTENANCE

7-1 Changing Address of Remote Control Unit in Indoor Unit

If you are installing more than 1 indoor unit (up to 2) in the same room, it is necessary for you to assign each unit
its own address, so each can be operated by its own separate remote control unit. You assign the addresses by
matching the remocon address on the PCB of each indoor unit with the switch positions of its remote control unit.
To change address on PCB
(1) Set the switch n.2 to "off" position on the address dip switch (S01)
(see detail on figure)
To change address on Remote Control Unit
NB.: Once changed, you cannot restore the original address
(1) Remove the batteries before changing the address
(2) Remove tab marked A to change the address of the remote control unit
(when is removed, the address is automatically set to B)
(3) After inserting the batteries, press ACL button