Installation Details; Wrench Torque Sheet For Installation; Connecting The Cables; Pipe Length And The Elevation - Midea MSV1-12HRDN1-MQ0W Service Manual

Table of Contents

Advertisement

7 Installation Details

7.1 Wrench torque sheet for
installation
Outside diameter
Torque
Ф6.35mm
1/4in
1500N.cm(153kgf.cm)
Ф9.52mm
3/8in
2500N.cm(255kgf.cm)
Ф12.7mm
1/2in
3500N.cm(357kgf.cm)
Ф15.9mm
5/8in
4500N.cm(459kgf.cm)
Ф19mm
3/4in
6500N.cm(663kgf.cm)

7.2 Connecting the cables

The power cord should be selected according
to the following specifications sheet.
Appliance Amps
10
13
18
25
30
The cable size and the current of the fuse or
switch are determined by the maximum
current indicated on the nameplate which
located on the side panel of the unit. Please
refer to the nameplate before selecting the
cable, fuse and switch.
Additional tightening
torque
1600N.cm(163kgf.cm)
2600N.cm(265kgf.cm)
3600N.cm(367kgf.cm)
4700N.cm(479kgf.cm)
6700N.cm(683kgf.cm)
AWG Wire Size
18
16
14
12
10

7.3 Pipe length and the elevation

Models
MSV1-09HRFN1-MT0W+MOC-09HFN1-MT0W
MSV1-12HRFN1-MT0W+MOC-12HFN1-MT0W
MSV1-12HRDN1-MQ0W+MOC-12HDN1-MQ0W
MSV1-18HRDN1-MQ0W+MOF-18HDN1-MQ0W
MSV1-24HRDN1-MQ0W+MOG-24HDN1-MQ0W
Models
MSV1-09HRFN1-MT0W+
MOC-09HFN1-MT0W
MSV1-12HRFN1-MT0W+
MOC-12HFN1-MT0W
MSV1-12HRDN1-MQ0W+
MOC-12HDN1-MQ0W
MSV1-18HRDN1-MQ0W+
MOF-18HDN1-MQ0W
MSV1-24HRDN1-MQ0W+
MOG-24HDN1-MQ0W
29
Pipe size
Gas
3/8in
(Ф9.52mm)
1/2in
(Ф12.7mm)
1/2in
(Ф12.7mm)
5/8in
(Ф15.9mm)
Max.
Standard
Max.
Length
length
Elevation
A
7.5m
10m
25m
(0.3in)
(0.39in)
(0.98in)
7.5m
10m
25m
(0.3in)
(0.39in)
(0.98in)
7.5m
20m
30m
(0.3in)
(0.79in)
(1.18in)
7.5m
25m
50m
(0.3in)
(0.98in)
(1.97in)
Liquid
1/4in
(Ф6.35mm)
1/4in
(Ф6.35mm)
1/4in
(Ф6.35mm)
3/8in
(Ф9.52mm)
Additional
refrigerant
20g/m
20g/m
40g/m
40g/m

Advertisement

Table of Contents
loading

Table of Contents