UTICA BOILERS Trifire 3 Series Installation, Operation & Maintenance Manual page 52

Table of Contents

Advertisement

Table 15 - Riello 40F Chimney Vent Preliminary Burner Settings
Burner settings provided are for initial startup only. Final adjustments must be made using combustion test
instruments.
TABLE 15: RIELLO 40F CHIMNEY VENT PRELIMINARY BURNER SETTINGS
Boiler
Head
Insertion
Model
Type
Depth
4075
Reverse
2.75"
4090
Reverse
5100
Standard
2.75"
5120
Standard
2.75"
6130
Standard
2.75"
6145
Standard
2.75"
7165
Standard
2.75"
7180
Standard
2.75"
Timings
Pre-purge
12 seconds
17 - OIL BURNER, NOZZLE, & AIR SETTINGS
Firing
Combustion
Rate
Liner
[GPH]
0.75
0.90
2.75"
1.00
None
1.20
None
1.30
1.45
1.65
1.80
Nozzle
Nozzle
Mfr.
Type
Oval
Delavan
0.65 x 60W
Oval
Delavan
0.75 x 90B
Delavan
0.80 x 90B
Delavan
1.00 x 90B
V6
Delavan
1.10 x 80B
V6
Delavan
1.20 x 80B
V7
Delavan
1.35 x 45B
V7
Delavan
1.5 x 45B
52
Pump
Head
Air
Pressure
Setting
Setting
[PSI]
150
1
3.6
140
2
3.5
180
0
2.75
190
0
5.9
170
1
5.5
185
3
3.9
190
1
4.2
167
1
4.2
Riello
ECR Oil
Boiler
Oil
Burner Part
Model
Burner
Number
Model
4075
40F3
550003548
4090
40F3
550004237
5100
40F5
550004287
5120
40F5
550004290
6130
40F5
550004288
6145
40F5
550004291
7165
40F10
550004289
7180
40F10
550004292
PN 240013415 REV A [08/15/2021]
Rated
AFUE
Efficiency
[%]
87.0
86.0
87.0
86.0
87.0
86.0
87.0
86.0

Advertisement

Table of Contents
loading

Table of Contents