Mitsubishi Heavy Industries FDT100VNP1VF2 Technical Manual page 114

Standard inverter packaged air-conditioners
Table of Contents

Advertisement

(4)
Timer operation
(a) RC-EX1A
(i)
Sleep timer
Set the time from the start to stop of operation. The time can be selected in the range from 30 to 240 minutes (in the
unit of 10-minute).
Note (1) Enable the "Sleep timer" setting from the remote control. If the setting is enabled, the timer operates at every time.
(ii)
Set OFF timer by hour
Set the time to stop the unit after operation, in the range from 1 to 12 hours (in the unit of hour).
(iii)
Set ON timer by hour
Set the time to start the unit after the stop of operation, in the range from 1 to 12 hours (in the unit of hour). It is
allowed also to set simultaneously the indoor temperature, operation mode, air flow rate and warm-up enabled/
disabled.
(iv)
Set ON timer by clock
Set the time to start operation. The time can be set in the unit of 5-minute. This setting can be activated only once
or at every time. It is allowed also to set simultaneously the indoor temperature, operation mode, air flow rate and
warm-up enabled/disabled.
Note (1) It is necessary to set the clock to use this timer.
(v)
Set OFF timer by clock
Set the time to stop operation. The time can be set in the unit of 5-minute. This setting can be activated only once or
at every time.
Note (1) It is necessary to set the clock to use this timer.
(vi)
Weekly timer
Set the ON or OFF timer for a week. Up to 8 patterns can be set for a day. The day-off setting is provided for
holidays and non-business days.
Note (1) It is necessary to set the clock to use the weekly timer.
(vii) Combination of patterns which can be set for the timer operations
Sleep time
Set OFF timer by hour
Set ON timer by hour
Set OFF timer by clock
Set ON timer by clock
Weekly timer
Note (1) �: Allowed �: Not
(b) RC-E5
(i)
Sleep timer
Set the duration of time from the present to the time to turn off the air-conditioner.
It can be selected from 10 steps in the range from "OFF 1 hour later" to "OFF 10 hours later". After the sleep timer
setting, the remaining time is displayed with progress of time in the unit of hour.
(ii)
OFF timer
Time to turn OFF the air-conditioner can be set in the unit of 10 minutes.
(iii)
ON timer
Time to turn ON the air-conditioner can be set. Indoor temperature can be set simultaneously.
(iv)
Weekly timer
Timer operation (ON timer, OFF timer) can be set up to 4 times a day for each weekday.
(v)
Timer operations which can be set in combination
Item
Item
Timer
OFF timer
ON timer
Weekly timer
Note (1) �: Allowed �: Not
(2) Since the ON timer, sleep timerand OFF timer are set in parallel, when the times to turn ON and OFF the air-conditioner are duplicated, the set-
ting of the OFF timer has priority.
Sleep time
Set OFF timer by hour
Timer
OFF timer
Set ON timer by hour Set OFF timer by clock Set ON timer by clock
ON timer
113
-
-
'16 • PAC-T-240
Weekly timer
Weekly timer

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents