C. How to Remove Panels

1. Icemaker

• Front Panel: Remove the screw. Lift up and towards you.
• Top Panel: Lift off.
• Right Side Panel: Remove the screw.
Slide forward slightly and lift off.
• Insulation Panel: Remove the
thumbscrews. Lift up slightly and pull
towards you.
• Top Insulation: Lift off.
• Front Frame: NOTICE! Leave the
front frame in place until "II.D.2
Water Tank Removal."

2. Remote Condensing Unit

• Top Panel: Remove the screws and lift off.
• Front Panel: Remove the screws and lift off.
• Left Side/Lower Panel (L1): Remove the screws and lift off.
• Left Side/Upper Panel Left (L2): Remove the screws and lift off.
• Left Side/Upper Panel Right (L3): Remove the screws and lift off.
• Louver Panel: Remove the screws and lift off.
• Right Side Panel: Remove the screws and lift off.
Left Side/Upper Panel Left (L2)
Left Side/Lower Panel (L1)
Left Side/Upper Panel Right (L3)
Top Panel
Remote Condensing Unit
12
Top Panel
Insulation
Panel
Front Panel
Icemaker
Legs
Front Panel
Top Insulation
Front Frame
Right Side Panel
Fig. 3
Right Side Panel
Louver Panel
Fig. 4