12) Open the icemaker service valves first, then open the remote condensing unit service
valves.
13) Replace the service valve caps and tighten.
14) Insulate all exposed tubing and fittings.
Hoshizaki Technical Support is available at 1-800-233-1940 for recommendations.
Remote Condensing Unit
(with compressor)
Max.
16.5
Feet
Suction Line
"S" Oil-Trap
Max.
16.5
Feet
Service Loop
1/2" OD
Liquid Line
(insulated)
3/4" OD Suction Line
(insulated)
Icemaker
Bin
Service
Loop
3/4" OD Suction Line
(insulated)
1/2" OD
Liquid Line
(insulated)
Fig. 14