INSTALLATION
REGULATORY REQUIREMENTS
•
The heater must be installed in accordance with the manufacturers installation instructions.
•
The heater MUST ONLY be installed or removed by an authorised person.
•
The heater MUST be installed in accordance with AS/NZS 3000 and all other applicable local municipal
building codes including OH&S requirements
UNPACKING
If any damage is present DO NOT INSTALL or OPERATE the appliance and contact your supplier
for advice.
IMPORTANT
APPROXIMATE HEATING AREA
C
OUTDOOR RADIANT HEATER MOUNTING
This outdoor radiant heater comes with a pair of stainless steel adjustable angle mounting brackets. The adjustable
angle enables the heater to be installed on vertical, horizontal and inclined surfaces.
Inclined ceiling mount
The ideal mounting position is directly above the area to be heated with a longitudinal orientation and facing
vertically downwards. If this is not possible, the heater(s) can be mounted on a wall and angled downwards. For
this application ensure the mounting height is within 2.1m to 2.7m.
Correct Installation
CEILING
The heater must never be installed in the upwards or inwards facing position, the heating surface
must always be positioned to direct the heat in a downwards or outwards direction.
WARNING
Rinnai
Dimension
A
B
Dimension
Horizontal ceiling mount
CEILING
Indoor Area Spot Heating
ORH15SR
A
1030
B
1700
C
2150
Outdoor Covered / Enclosed Area
ORH15SR
A
1030
B
1400
C
2150
Angled horizontal ceiling mount
Incorrect Installation
10
ORH18MR
ORH24LR
1210
1490
2050
2650
2150
2150
ORH18MR
ORH24LR
1210
1490
1600
2050
2150
2150
Vertical wall mount
CEILING
ORH32XLR
1900
3550
2150
ORH32XLR
1900
2750
2150
CEILING
ORH OIM