If engine fires, but does not continue to
NOTICE:
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT: Do not overload generator or individual
panel receptacles. These outlets are overload protected
with push-to-reset circuit breakers. If amperage rating of
any circuit breaker is exceeded, that breaker opens and
electrical output to that receptacle is lost. Read
Generator Limits
carefully.

Generator Shut Down

Equipment and property damage. Dis-
CAUTION
connect electrical loads prior to start-
ing or stopping unit. Failure to do so could result in
equipment and property damage.
Shut off all loads and unplug electrical loads from generator
1.
panel receptacles.
Let engine run at no-load for several minutes to stabilize
2.
internal temperatures of engine and generator.
Move Run/Stop switch to Stop.
3.
Close fuel valve.
4.
Under normal conditions, close fuel
NOTICE:
valve and allow generator to run carbure-
tor bowl out of fuel. For emergencies, switch to Stop.

Low Oil Level Shutdown System

The engine is equipped with a low oil level sensor that
shuts down the engine automatically when the oil level
drops below a specified level. The engine will not run
until the oil has been filled to the proper level.
If the engine shuts down and there is sufficient fuel,
check engine oil level.
Owner's Manual for Portable Generator
Know
Operation
15