4.6 Definitions
Set pressure is defined as that pressure where the dome pressure is 15% of the supply pressure.
Crack pressure is defined as the supply pressure were gas flow begins at the pilot exhaust.
Adjustable pressure regulator
(relieving type)
Supply pressure gauge
Supply pressure
FIGURE 6
½" (1.5 mm)
FNPT ports
Supply port
Supply
Vent
Accumulator
½" (1.5 mm) Pipe
Optional bench set-up
Pilot only
Recommended test set-up
Pressure adjustment
Pilot valve to be set
Blowdown adjustment
Dome pressure gauge
Pressure adjustment
Blowdown adjustment
Dome pressure gauge
9