During the process of cooling, some water will be extracted from the air into the unit. If the reservoir is full:
On the mechanical model the compressor will stop. The fan will continue to circulate the air. The 'FULL WATER'
indicator will illuminate to remind you.
To re-start the unit empty the collected water in one the following ways:
1.
Turn off the air conditioner and avoid
moving it when full.
2. Position the water tray underneath the drain
hole.
3.
Remove the with drain cap & rubber plug from
the drain hole and allow the water to drain
out.
4.
When the water tray is almost full, replace
the rubber plug in the drain hole and empty
the water tray.
5.
Repeat until the unit is emptied.
6. Replace the rubber plug and tighten the
with drain cap firmly.
7. Switch on the unit - the comp light should
not be flashing.
If you wish to operate the unit without the need to empty the water tank, please:
Remove the with drain cap and rubber plug
and retain for future use.
Connect the drain tube supplied to the
water outlet as shown and locate the
other end into a drain.
The drain tube may be extended by
adding an extension tube and using a
suitable connector, (not supplied by the
manufacturer).
Please note
1.
The drain must be at or below the
outlet level.
2. Flashing comp / 'full water' indicator will
not function in this mode of drainage.
3.
If you want to extend the water tube,
you can connect it with another tube
(OD: 18mm)
DRAINAGE
with drain cap
with drain cap