Advertisement

Table 2
Alternative
Calibration Points
The calibration
weight should be
removed from the
weigh platter before
countdown com-
pletes.
16
Model 6712 Point-of-Sale Interface Scale User's Manual
Capacity
150 lb
75 kg
100 lb
50 kg
1600 oz (100 lb)
50 lb
25 kg
800 oz (50 lb)
30 lb
15 kg
7 kg
160 oz (10 lb)
5 lb
2.5 kg
80 oz (5 lb)
* For convenience, span weight values are
prompted in POUNDS for ounce calibrations.
8. Place chosen calibration weight on the weigh
platter and press the TEST key...
After a brief wait, DONE is displayed.
9.
Press SW-1...
The unit will perform a display countdown
and then return to normal weighing
mode.
The unit is now tested, configured and calibrated.
It is ready for use in your application.
Alternative
Calibration Weights
10 lb, 50 lb
10 kg, 50 kg
10 lb, 50 lb
10 kg, 25 kg
10 lb, 50 lb*
10 lb, 25 lb
2 kg, 5 kg
10 lb, 25 lb*
5 lb, 10, lb
2 kg, 5 kg
2 kg, 5 kg
2 lb, 5 lb*
1 lb, 2 lb
1 kg
1 lb, 2 lb*