Dimensions - Amana AMVS80-U Quick Start Manual

Single-stage, variable-speed ecm, multi-position, ultra-low nox gas furnace

Advertisement

AMVS80-U Dimensions
Alternate Gas Inlet
High-Voltage Inlet
Low-Voltage Inlet
28"
Model
AMVS800604BU*
AMVS800805CU*
Notes
• Line voltage wiring can enter through the right or left side of furnace.
Low-voltage wiring can enter through the right or left side of furnace.
Minimum Clearances to Combustible Materials
Sides
Rear
1"
0"
¹
24" clearance for serviceability recommended.
² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas
Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and
CAN/CSA B142.2 (in Canada).
Note: AMVS80 approved for line contact in the horizontal position.
4
1¾"
A
B
27⅞"
20"
13¼"
A
B
17½"
16"
21"
19½"
Vent²
Front¹
SW
3"
6"
www.amana-hac.com
1 ⁄ "
33⅜"
23 ⁄ "
Top
B
1"
1"
Alt. Flue Outlet — Horizontal Left
19½"
Alt. Gas Inlet
Alt. High Voltage
15"
Alt. Low Voltage
23"
SS-AMVS80-U