Sperry instruments DSAG00TRMS Operating Instructions Manual
Sperry instruments DSAG00TRMS Operating Instructions Manual

Sperry instruments DSAG00TRMS Operating Instructions Manual

Digital clamp meter

Advertisement

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
SPERRY
INSTRUMENTS
IMPORTANT: RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. If you find damage,
notify the carrier at once.
Frequency / Duty Cycle (Hz/%)
Relative Measurement (INR/REL)
Figure 2
Data Hold
-
Negative Value
REL
Relative Measurement
AUTO
Auto Ranging
INRUSH
Inrush Current Measurement
DC
Direct current
-----------------------1-----------------------
®
Clamp Jaw
Light
----+ +- ­
Inrush Current / -------,f-+�
AC
Alternating current
Diode Check
11()4
Audible Continuity Check
PMAX
Peak maximum value
PMIN
Peak minimum value
PMAX-
Peak to Peak value
MIN
OPERATING INSTRUCTIONS
DIGIT AL CLAMP METER
Model DSAG00TRMS
NOT
Shipping damage is
covered by warranty. The carrier is responsible
for all repair or replacement costs resulting from damage in shipment.
□□
H-+ - -- Clamp Light
-M/10-P<MEROFF
*Prus2Sec
DSAllOOTRMS
Figure 1
Low Battery
Nanofarad, Microfarad,
nF, µF, mF
Millifarad (Capacitance)
mV, V
Millivolt, Volt
A
Ampere (Current)
Ohm, Kiloohm, Megaohm
O, kO,MQ
(Resistance)
Hertz, Kilohertz,
Hz, kHz, MHz
Megahertz (Frequency)
HOLD / Backlight /
NCV
Non-contact Voltage Detection
OF
Degrees Fahrenheit
·c
Degrees Celsius
Duty Cycle
%
OL
Overload
EF
Electric Field Detection

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSAG00TRMS and is the answer not in the manual?

Questions and answers

Summary of Contents for Sperry instruments DSAG00TRMS

  • Page 1 ® SPERRY OPERATING INSTRUCTIONS DIGIT AL CLAMP METER INSTRUMENTS Model DSAG00TRMS IMPORTANT: RECEIVING INSTRUCTIONS Shipping damage is covered by warranty. The carrier is responsible Visually inspect all components for shipping damage. If you find damage, for all repair or replacement costs resulting from damage in shipment.
  • Page 3 ,&WARNING • Never attempt to make any measurement if any abnormal conditions are noted, such as broken case, cracked test leads and exposed metal part. • Do not tum the function selector switch with plugged in test leads connected to the circuit under test. •...
  • Page 5: Preparation For Measurement

    3-2. General Specification • The maximum voltage allowed between terminal and ground: 1000 VDC or 750 VAC • Altitude: Maximum 2000m • Display: 5999 count Backlit LCD • Sampling time: ~ 3 times / sec • Automatic power off: 15 Minutes (Unless disabled) •...
  • Page 6 5-2. Resistance / Continuity / Diode / Capacitance Resistance Diode test 1. Install the test leads 1. Install the test leads 2. Rotate the dial to the position 2. Rotate the dial to the position 3. Confirm “OL” is displayed on the LCD screen 3.
  • Page 7: Relative Measurement

    6. Press the trigger to open the clamp jaws and place the jaws around a single conductor. (Easily accomplished with the use of a line splitter) 7. Turn on the device being tested 8. The inrush current during the 100ms after start-up will be displayed on the LCD screen 9.
  • Page 9 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com DSA600TRMS 0416...