3) Filter Installation

This product features an easy-changing design that allows users to change the filter without
shutting off the water supply. To install the filter, follow the steps listed below.
Precautions
A. Make clean cuts on the tube to ensure a tight, sealed connection.
B. Always use the C-clips to secure the quick-fitting connections.
C. After assembly, check to ensure the connection is not leaking.
Step 1
Remove the
COVERS AND RUBBER PLUGS
Step 2
Install each filter in the appropriate slot with the name of the filter listed on the side:
1. The composite filter is mounted to the bottom slot.
2. The reverse osmosis membrane is mounted to the top slot.
3. The post carbon filter or alkaline filter is mounted to the slot located in the middle.
www.123filter.com
| (678) 261-7611 |
on the upper end of each filter.