1) Starting for the First Time

A. To start the system, plug it in, turn on the feed water adapter, then turn on the faucet. Vibrations
can be expected as the pump starts.
B. Rinse the RO membrane for 5 minutes.
C.
Turn on the faucet and let it run for at least 30 minutes to flush the system. This should be done
each time the filters are changed.
D. During this time, carefully check all fittings for a secure connection. Use a damp paper towel to
wipe clean and verify that no connections are leaking.
E. Once the rinsing is completed, turn the faucet off and check again for leaks. If no leaks are
present, the system is ready for use.

2) Routine Maintenance

• If you will not use the system for two weeks or longer, disconnect the water supply, drain
the system, and disconnect the power.
• Follow the recommended filter replacement schedule. Replace the filter any time the
indicator is on. Note that the actual filter life depends on the family size and water source
quality. Failure to replace the filter at the appropriate times can damage the system and
potentially cause health hazards.
Precautions for Changing the Filters
A. Unscrew the filter to be replaced counterclockwise and relieve the pressure.
B. Screw the corresponding replacement filter into each slot.
C. After replacing the filter, flush the system by running the water for at least 30 minutes after
installing a new filter(s).
D. Reset the filter status. Please refer to the "Filter Service Life Reset" part.