7543
Disables all stations in all satellites (rain shutdown). Note: Satellite address code is not used
with 7543 or 7544 command codes. The stations will not respond to any further commands until
enabled.
7544
Enables operation of all stations in all satellites. See Note above.
7546
Sequentially syringes all stations for a set length of time; e.g., 7546 turns on all stations for the
predetermined number of 30 second intervals as defined in the syringe time.
8000
Disables pump start.
8001
Enables pump start to be assigned to a station; e.g., 8001 48 assigns pump start to station 48.
8003 00
Disables operation and turns off all stations in the satellite with sequential shutdown.
8003 01
Enables operation of all stations in the satellite.
8004
Changes the password; e.g., 8004 7531 6108 will change the factory default password (7531) to
6108.
8006 01
Sets the syringe time in 30-second intervals; e.g., 8006 01 0100 (without a password) or 8006
pppp 01 0100 (with a password) sets the syringe time to 100 intervals (50 minutes). The number
of intervals must be given as four digits with leading zeros but can be no greater than 0255.
8006 03
Enables/disables the password. Use 8007 03 01 to enable password protection or 8007 03 00
to cancel password protection.
8008
Configures stations as switches. Stations can be specified individually and in combination with
a range of stations; e.g., 8008 01 12 50 – 60 configures stations 1, 12 and 50 through 60 as
switches. Note: Only a single dash is used when entering a range of stations.
8009
Configures stations for irrigation. Stations can be specified individually and in combination with
a range of stations; e.g., 8009 01 20 45 – 48 configures stations 1, 20 and 45 through 48 for
irrigation.
8011
Resets to factory defaults.

Advertisement

Table of Contents
loading

Table of Contents