Type ME43 able of conTenTs Operating instructiOns ........................6 symbols ............................6 1.2 Definition of terms ........................7 intended use ............................7 Basic safety instructiOns ......................8 general nOtes...........................9 4.1 Contact addresses ........................9 4.2 Warranty ............................9 4.3 Information on the Internet ......................9 prOduct descriptiOn ........................10 technical data ..........................11 6.1 Conformity ..........................11 6.2 Standards ...........................11...
Page 4
Type ME43 7.3 Establish connection to the fieldbus ..................16 7.3.1 Industrial Ethernet .......................16 7.3.2 PROFIBUS version .....................17 7.3.3 CC-Link version ......................17 MicrO sd card ..........................18 cOMMissiOning with fieldBus gateway ..................20 9.1 Operating elements ........................20 9.2 Operation with the display ......................20 9.3 Protocol settings for connecting the device to the PLC network ..........21 9.3.1 Selecting the protocol ....................21 9.3.2 Enter address ......................21...
Page 5
Type ME43 11.4 Logging onto the web server .....................42 11.5 Passwords ..........................43 11.5.1 Change password .......................43 11.5.2 Factory reset of password ..................43 11.6 Configuring the device .......................43 Opc ua ..............................44 12.1 General description ........................44 12.2 Establish connection with OPC UA ...................44 12.2.1 Settings on the device ....................44 12.2.2 Settings for the OPC UA client ...................45 12.3 Server certificate ........................45...
Type ME43 Operating instructions OpEraTing insTrucTiOns The operating instructions describe the entire life cycle of the device. Keep these instructions ready to hand at the operation site. Important safety information. ▶ Read these instructions carefully. ▶ Observe in particular the safety instructions, intended use and operating conditions.
Definition of terms Definition of the terms used in these instructions. • Device: the term “Device” stands for the following device types: ME43 • Ex area: the term “Ex area” stands for potentially explosive atmosphere • Ex approval: the term “Ex approval” stands for approval in the potentially explosive atmosphere •...
Type ME43 Basic safety instructions Basic safETy insTrucTiOns These safety instructions do not take into account any unforeseen circumstances and events which occur during installation, operation and maintenance. The operator is responsible for observing the location-specific safety regulations, also with reference to personnel. General hazardous situations. To prevent injuries, observe the following: ▶ Use the device only when it is in perfect condition and in accordance with the operating instructions.
Type ME43 General notes gEnEral nOTEs Contact addresses germany Bürkert Fluid Control Systems Sales Centre Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940 - 10-91 111 Fax + 49 (0) 7940 - 10-91 448 E-mail: info@burkert.com international The contact addresses can be found online at: www.burkert.com Warranty A precondition for the warranty is that the device is used as intended in consideration of the specified oper- ating conditions. Information on the Internet Operating instructions and data sheets for the Bürkert products can be found on the Internet at: www.burkert.com...
EtherCAT Table 1: Application area Type ME43 The Bürkert Communicator software is required to configure the fieldbus gateway. The Bürkert Communicator software can be downloaded free of charge from the Bürkert website. In addition to the software, the USB-büS interface set 1 – which is available as an accessory – is required. See chapter “17 Accessories”.
Operating conditions note Malfunction due to heat and heavy frost. ▶ Do not use the device outside the specified ambient temperature. Ambient temperature –20…+60 °C Altitude Up to 2000 m above sea level Mechanical data Dimensions See data sheet for type ME43 Housing material Polycarbonate Electrical data Supply voltage: 24 V ±10 % – residual ripple 10 % Power consumption: < 2 W Degree of protection: IP 20 to EN 60529 / IEC 60529 (only with correctly connected cables or plugs and sockets) verified by Bürkert, not evaluated by UL...
Type ME43 Technical data 6.6.4 prOfiBus dpV1 DP V1 Class 1 Read / Write Acyclic communication DP V1 Class 2 Read / Write / Data Transport Fixed values from 9.6 kbit/s to 12 Mbit/s Transmission speed Autodetect mode is supported Input data: 244 Byte Maximum size of the transferred data Output data: 244 Byte 6.6.5 EtherCAT Maximum quantity of cyclical input and output data 512 Bytes...
After activating the OPC UA, other server settings will become visible. Note chapter “12” on this topic. Type label, device labelling Identification number of device Type Serial number ID: 00307390 S/N: 001001 Type: ME43 W1XXXX Data matrix code Manufacture code (link for further information on the CE mark device) Permitted ambient temperature -20 °C...+60 °C...
Type ME43 Installation insTallaTiOn Warning Risk of injury due to improper installation. ▶ Installation may be carried out by authorised technicians only and with the appropriate tools. ▶ Secure the system against unintentional activation. ▶ Following installation, ensure a controlled restart. Mounting the device onto the standard rail →...
Type ME43 Installation Electrically connecting the device → Connect 5-pin spring clamp terminal according to the assignment. Assignment 5-pin spring clamp terminal Plug view Terminal colour Description Supply voltage 24 V White CAN_H (büS connection) Green Shielding Blue CAN_L (büS connection) Black Table 2: Assignment 5-pin spring clamp terminal Establish connection to the fieldbus 7.3.1...
Type ME43 Installation 7.3.2 PROFIBUS version Remove D-Sub, 9-pin push-in connector. D-Sub, 9-pin Pin Signal Function Connection Not used Not used RxD/TxD-P Data line P (B conductor) Duty CNTR-P Repeater directional control optional DGND Ground for bus terminating resistor optional +5 V supply, bus terminating resistor...
► from your Bürkert sales department. Card slot for micro SD card Bonnet Figure 7: Change micro SD card; ME43 fieldbus gateway note Removing the SD card while the power supply is on can lead to data loss and damage to the card. Do not remove the SD card while the device is connected to the supply voltage. ►...
Page 19
Type ME43 Micro SD card Removing the micro SD card: → Pull the bonnet carefully out of the recess. → Turn the bonnet away from the top left. → To unlock, press on the edge of the engaged micro SD card.
Type ME43 Commissioning with fieldbus gateway cOMMissiOning wiTh fiEldBus gaTEway Operating elements Arrow key, up arrow Arrow key, down arrow Menu button Bonnet Card slot for micro SD card Figure 8: Overview of the operating elements Operation with the display The display is operated with the two arrow keys and the round menu key.
Type ME43 Commissioning with fieldbus gateway Protocol settings for connecting the device to the PLC network Selection of the appropriate fieldbus protocol is a requirement for configuration of the device and connection to the network. If devices feature a PROFIBUS interface and CC-Link interface, the fieldbus protocol has been preset at the factory. 9.3.1 Selecting the protocol → Press menu button twice. → Select Parameter. → Select Protocol. 9.3.2...
ICom version IComm version is displayed DEVReplace can be used in conjunction with the configuration provider Table 4: Settings on the display of the ME43 fieldbus gateway Only available with PROFIBUS DPV1 Only available with CC-Link Only for EtherNet/IP Only available for PROFINET, EtherNet/IP and Modbus TCP Only available for PROFINET, EtherNet/IP, EtherCAT and Modbus TCP...
Options Tools Help General settings Home page Parameters Diagnostics Maintenance Desktop Status LED Graph büS büS on COM3 Alarm limits Fieldbus gateway ME43 Diagnostics EtherNet/IP Configuration provider General settings Managing device functions System monitoring Display Zoom 100% Configuration areas of the Menus device Detailed views...
Type ME43 Start-up with Bürkert Communicator 10.2 Connecting the device to the Bürkert Communicator The Bürkert Communicator can be connected to the device via a büS network or with the büS stick. → Install Bürkert Communicator on the PC. → Use the USB-büS-interface to establish the connection between the device and the PC.
Type ME43 Start-up with Bürkert Communicator 10.3.4 Entering the EtherCAT address (Station Alias) (Protocol name) > Parameters > EtherCAT settings > Station Alias Begin Startup wizard → Enter address. Valid addresses: 0...65536. If an address outside the valid range has been set, the device will issue an error message. 10.3.5 Enter parameters for EthernetNET/IP, PROFINET, Modbus TCP, Ethercat, CC-Link IE filed basic With Modbus TCP, it is essential to set the Ethernet parameters.
PROFIBUS DPV1 PROFINET 1024 EtherNet/IP 1008 Modbus TCP 2048 EtherCAT 1024 (ME43 to A.03.02.00) EtherCAT 1024 (ME43 from A.7.5) Table 5: Maximum number of data values 10.4.1 Downloading a gateway configuration If a configuration file from an earlier project is present, the device can be configured directly using this. > > > (Protocol name) Parameters Gateway configuration Download a gateway configuration file →...
Page 27
Type ME43 Start-up with Bürkert Communicator 10.4.4.4 Edit general settings Create a gateway configuration General settings General device settings Information on entries, see “Table Product code 1296380467 6: Meaning of the input fields” Product family Gateway Product name ME43 Description Gateway_ME43_bueS Default network settings IP address of the gateway 192.168.0.100...
Page 28
Type ME43 Start-up with Bürkert Communicator 10.4.5.5 Declaring inputs and outputs for the Gateway configuration Create a gateway configuration Declare inputs and outputs Groups/devices – Products – Electromotive valves 0030739000000001 332x E_Process_Valve 336x E_Process_Valve Inputs and outputs 328x Motor Control Valve...
Page 29
Type ME43 Start-up with Bürkert Communicator Values for declaring inputs and outputs have been predefined in the Add device(s) dialog box. Add device(s) Settings Values per device Device name (prefix for all value names) Number SP_IO Maximum possible number of inputs PV_IO Maximum possible number of outputs CMD_IO XCO_DO1 Device configuration XCO_DO2 Positioner DigitalIn CMD_GW Process controller SP_GW...
Page 30
Type ME43 Start-up with Bürkert Communicator Context-related definition of the values • Input values Icon: Input values are values which come from the büS participant and are read by the PLC (büS participant → Fieldbus gateway → PLC) • Output values Icon: O Output values are values which are written from the PLC to the büS participant/fieldbus gateway. Output value...
Page 31
Type ME43 Start-up with Bürkert Communicator 10.4.6.6 Fieldbus-specific address mapping → Check editable fields and complete if required. The protocol-specific settings are explained in the following screenshots. → Press Continue. Address mapping for EtherNet/IP: Create a gateway configuration EtherNet/IP settings EthernetIP Data Major revision Minor revision Order number EtherNet/IP EDS revision EtherNet/IP product type Generic device, keyable (43)
Page 32
Type ME43 Start-up with Bürkert Communicator Address mapping for PROFINET: Create a gateway configuration Profinet Header info Main family Gateway Information Gateway_ME43_bueS Device ID 0x23 Device access point info Advanced Module ID Minimum cycle time of the gateway 0x100 Hardware version Software version A.01.01.00...
Page 33
Type ME43 Start-up with Bürkert Communicator Address mapping for Modbus TCP: Create a gateway configuration Modbus TCP settings Bus ident data Device name: MajorMinorRev MEX3 Addressing Automatic modbus TCP addressing Use Modbus FC03 if possible Start address 0 Start Coil/register addressing Reset devices Start address 1...
Page 34
Type ME43 Start-up with Bürkert Communicator Address mapping for EtherCAT: Create a gateway configuration EtherCAT EtherCAT data EtherCAT product code Product code of the EtherCAT device must be a whole number, e. g.: 12345678 #xFDF9 EtherCAT revision EtherCAT revision of the device must be an 8-digit hex number beginning with #x ..
Page 35
Type ME43 Start-up with Bürkert Communicator Address Mapping for CC-Link: Create a gateway configuration CC-Link gui.gateway.CC-Linkdata 2 Station & Extension Cycle: SINGLE gui.gateway.cclinkstationcycles Addressing Automatic CC-Link addressing Start Reset devices Cyclic Name Index Subindex Start address EVA_POS 0x2540 0x01 0x000 EVA_NamurStatus 0x2541 0x01 0x00C...
Page 36
Type ME43 Start-up with Bürkert Communicator 10.4.7.7 Saving the gateway configuration Create a gateway configuration Final settings Select output directory Search Output directory C:\User\Max.Mustermann\AppData\Comuni Create new major version Back Cancel Continue Figure 20: Output directory selection → Select the output directory in the Final settings dialog box.
Page 37
Type ME43 Start-up with Bürkert Communicator Gateway configuration files Storage folder Description Files for CC-Link 0x1640_GatewayME43_4_V2.0_E4.cspp PLC_CCLink Device description file. Import to the PLC help_cclink.csv PLC_CCLink Overview of the cyclical and acyclic device values. Files for EtherCAT EtherCAT-Buerkert-Gateway-date-.xml PLC_EtherCAT Device description file. Optional: Import to the PLC help_ethercat.csv PLC_EtherCAT Overview of the cyclical and acyclic device values.
Type ME43 Start-up with Bürkert Communicator 10.5 büS network 10.5.1 Set up büS network The task of the fieldbus gateway is to convert process values between an Industrial Ethernet PLC and büS participants. To do this, the ME43 fieldbus gateway must be configured and parameterised. Selection of the büS participants that are to communicate with the PLC via the ME43 fieldbus gateway: Fieldbus gateway büS participant 1 büS participant 2 Figure 21: Configuration; selecting the büS participants that are to communicate with the PLC Selecting which process values are to be converted from “Industrial Ethernet” to “büS”: Fieldbus gateway Target value 1 büS participant 1 Actual value 1 Target value 2 büS participant 2...
Page 39
Type ME43 Start-up with Bürkert Communicator Define the direction for the transmission of the process values (from/to PLC, from/to büS participant): The direction is assigned in the büS fieldbus from the viewpoint of the ME43 fieldbus gateway. Example: - Set-point values of a büS participant are output values of the ME43 fieldbus gateway. - Actual values of a büS participant are input values of the ME43 fieldbus gateway. Process output values of the PLC are recorded in the ME43 fieldbus gateway as process input values by Industrial Ethernet. These process input values are converted and output as process output values by büS. Conversely, process output values of the büS participant are recorded as büS input values. These process input values are converted and output as process output values via Industrial Ethernet.
Type ME43 Start-up with Bürkert Communicator 10.5.2 Configuring the büS network A büS network configuration is required to connect other büS devices successfully to the system and to connect to Type ME43. → büS Select in the navigation area. → Select Detail view büS map. COMMUNICATOR Edit File Communication View Options Tools Help büS Overview büS Map Home page...
Type ME43 Start-up using a web server sTarT-up using a wEB sErVEr Fieldbus gateway type ME43 has an integrated web server that provides functions for the configuration and display of status information. The web server can be used for the following protocols: • PROFINET • EtherNet/IP • EtherCAT • Modbus TCP • CC-Link IE field basic The IP address of the device is used for access via the web server.
Type ME43 Start-up using a web server Figure 26: Web server view 11.4 Logging onto the web server → On the home page, click on Login on the top left. → Enter your user name and password: User name: admin Password: admin (or MAC address) →...
Type ME43 Start-up using a web server 11.5 Passwords note Security risk due to standard passwords. Unauthorized persons can log in to the web server and make changes to the system. Please change standard passwords. ► If the web server is not needed, disable access via Bürkert Communicator. ► Web server > Parameters > Deactivate web server. The following user names and passwords are active by default and are re-enabled when the passwords are...
12.1 General description The OPC UA server offers an OPC UA client the possibility to read and write the values (cyclical and acyclic) determined by the gateway configuration. To make the data of the ME43 and the connected büS devices available in an OPC UA client, the following points must be observed: • A gateway configuration with Communicator version 5.2 or higher must be carried out, acyclic values can also be selected. • Values that are available at the PLC via the set protocol and at the OPC client are identical and cannot be differentiated.
Authentication settings Anonymous 12.3 Server certificate The OPC UA server offers the user the possibility to exchange the factory server certificate for his own. The exchange is possible via the web server. Exchanging a certificate: → Open the web server with the IP address of the ME43. The certificate can only be changed after registration. → Select OPC UA Server. → Under Server certificate click the symbol and select the file in the format “DER”. →...
Page 46
Type ME43 OPC UA The device must be restarted after a successful exchange. Delete user-specific certificate and set the factory certificate to active: → Click Change certificate. → Confirm with <OK> After the restart, the factory certificate is loaded. When resetting to factory defaults, the user-specific certificate is deleted and the factory certificate is set to active. The user-specific certificate is not saved on a removable storage device and is therefore not transferred when the configuration is transferred to another device. English...
Type ME43 Display elements display ElEMEnTs LEDs for network connection to Industrial Ethernet (not available for PRO- Display FIBUS or CC-LINK variants) Status LED for indicating the device status Link LED (yellow) rJ45 Link/act LED (green) Figure 30: Overview of the display elements 13.1...
Type ME43 Display elements 13.2 LED for displaying the device status The LED that indicates the device status changes colour and status in accordance with NAMUR NE 107. If several device statuses exist simultaneously, the device status with the highest priority is displayed. The priority is based on the severity of the deviation from standard operation (red = failure = highest priority).
Type ME43 Bürkert Communicator menus BürkErT cOMMunicaTOr MEnus The following overview describes the device-specific settings for the type ME43 with the Bürkert Communi- cator software. It does not describe the basic operation of the software. Detailed information on using the Bürkert Communicator software can be found on the Bürkert → 8920 → “Operating instructions” downloads.
Type ME43 Bürkert Communicator menus 14.3 Configuration area “PROFINET”, “EtherNet/IP”, “EtherCAT” “Modbus TCP” and “CC-Link IE field basic” Detailed view Parameters Detailed view Menu Parameters PROFINET, EtherNet/IP, Initiate Startup wizard for input check and set start con- Modbus TCP or CC-Link ditions for büS communication. IE field basic settings IP parameter settings Set DNS compatible name.
Type ME43 Bürkert Communicator menus Maintenance detailed view Detailed Menu view Maintenance Version number Stack name In these menus, the current values are Stack version displayed, not set. Stack build Stack revision Stack date ICom version Hardware reset of indus- trial communication Table 13: Settings in the “PROFINET” configuration area, maintenance detailed view 14.4...
Type ME43 Bürkert Communicator menus 14.5 Configuration section “General settings” Detailed view “Parameter” Detailed view Menu Set operation mode Parameters Status LED Configuration of the büS interface büS Assign displayed name for display and Bürkert Communicator. Location Specify location displayed for the device. Description Enter description text for tooltips Advanced Unique device name for partner assignment.
Page 53
Type ME43 Bürkert Communicator menus Detailed view “Diagnostics” Detailed Menu view Diagnostics Device status Operating duration In these menus, the current Device temperature values are dis- Supply voltage played, not set. Voltage drops Number since restart. Min./max. values Max. temperature Min. temperature Max. Supply voltage Min. Supply voltage Device start counter Removable storage medium status Current system time Battery voltage büS status Receive errors Number since restart.
Page 54
Type ME43 Bürkert Communicator menus Maintenance detailed view Detailed view Setting Maintenance Device information Displayed name only displayed if a name In these menus, was entered in the menu of the same name the current values for the Parameters detailed view. are displayed, not set.
Type ME43 Replacing the device rEplacing ThE dEVicE Warning Risk of injury due to improper work on the device. ▶ The device may only be replaced by trained specialists with suitable tools. ▶ Secure the system against unintentional activation. ▶ Ensure a controlled restart after replacing the unit. 1. Switch off the supply voltage. 2. Remove 5-pin spring-loaded terminal.
Page 56
Replacing the device 5. Remove the micro SD card. Card slot for micro SD card Bonnet Figure 33: Change micro SD card; ME43 fieldbus gateway → Pull the bonnet carefully out of the recess. → Turn the bonnet away from the top left. →...
Type ME43 Troubleshooting TrOuBlEshOOTing Problem Possible cause Measure NAMUR LED goes out The power supply drops out peri- Use power supply with adequate periodically. odically; the device implements a power. reset each time. The voltage drop in the connection Increase cable cross-section.
Type ME43 Troubleshooting 16.1 Description of the error code Error code Description Overload detected. Overvoltage detected. Undervoltage detected. Voltage warning limit exceeded. Voltage warning limit undershot. Battery voltage warning limit undershot. Voltage drop detected. Excess temperature detected. Low temperature detected. Temperature warning limit exceeded.
Page 59
Type ME43 Troubleshooting Error code Description 33/12 Input value simulation active for at least 1 value. 33/13 Output value simulation active for at least 1 value. 33/14 Demo operation mode enabled. 33/15 User-triggered maintenance signal. 33/32768 1 status message present. 35/1 EEPROM error detected.
Page 60
Type ME43 Troubleshooting Error code Description 45/2048 büS event: saving of persistent büS data (do not switch off device). 45/2049 büS event: deletion of persistent büS data (do not switch off device). 45/2304 büS event: router for acyclickonfigurier data active. 45/2560 büS event: incorrect serial number. 45/2561 büS event: incorrect configuration of cyclical inputs (not enough filters). 45/2562 büS event: incorrect configuration of cyclical values. 45/2816 büS event: manager is active. 45/3072 büS event: monitored device failed. 45/3584 Wait for addressing. 45/4096 Error when initialising the device parameters.
Page 61
Type ME43 Troubleshooting Error code Description 52/15 The cycle times of the graphical f(x) program do not correspond to the associated function cycle time. Re-load the program back onto the device. 52/16 f(x) mapping is incorrect (mapping table invalid), reconfiguration required. 52/17 f(x) function waits for producers. (Are all inputs linked?) 52/18 Graphical program editor: no program loaded, load a program to the device.
Type ME43 Troubleshooting 16.2 Status indicators and measures Displaying the status LED Description Measure based on NAMUR NE 107 No colour No power is supplied to the device. Power is supplied to the device. Flashing The device was selected using the Deselect the device in Bürkert (applies to all colours) Bürkert Communicator software.
Type ME43 Accessories accEssOriEs Caution Risk of injury and/or damage due to incorrect parts. Incorrect accessories and unsuitable spare parts may cause personal injuries and damage to the device and the area around it. ▶ Use only original accessories and original spare parts from Bürkert. Accessories Order number USB büS interface set 1 (including power supply and Bürkert Communicator...
Type ME43 Disassembly disassEMBly Warning Risk of injury due to improper disassembly. ▶ Disassembly must only be performed by trained technical personnel. 1. Switch off the supply voltage 2. Remove 5-pin spring-loaded terminal. Figure 35: Remove 5-pin spring-loaded terminal 3. R emove the Ethernet cable from interfaces X2 and X2. On PROFIBUS variant and CC-Link variant: Remove D-Sub, 9-pin push-in connector. 4. Remove the device from the standard rail Figure 36: Removing device from standard rail → Push the device upward and detach it from the upper guide of the standard rail.
Type ME43 Transportation, storage, disposal TRANSPORTATION, STORAGE, DISPOSAL note Damage in transit due to inadequately protected devices. ▶ Protect the device against moisture and dirt in shock-resistant packaging during transportation. ▶ Observe permitted storage temperature. Incorrect storage may damage the device. ▶ Store the device in a dry and dust-free location. ▶ Storage temperature: -30 °C…+80 °C.
Page 66
Type ME43 Transportation, storage, disposal English...