▶ Persons, who work on the device, must read and understand these Installation ....................6 instructions. Start-up .................... 8 The operating instructions can be found on the Internet at: www.burkert.com Operation and function ..............8 symbols Disassembly ..................10 ▶ indicates an instruction to prevent risks.
Basic safETy insTrucTions These safety instructions do not consider any contingencies or incidents The fieldbus gateway type ME43 is used as a field bus converter which occur during installation, operation and maintenance. The operator between büS and Industrial Ethernet, PROFIBUS DPV1, CC-Link.
TEchnical daTa note! Conformity Electrostatic sensitive components and modules. The device contains electronic components which react sensitively to The device conforms to the EU Directives as per the EU Declaration of electrostatic discharge (ESD). Contact with electrostatically charged Conformity (if applicable). persons or objects are hazardous to these components.
Page 5
4.5 Electrical data SELV/ PELV with UL Recognized Over- current Protection dimensioned according Supply voltage 24 V ±10 % - residual ripple 10% to UL/ IEC 61010-1 Table 18 Power consumption < 2 W NEC Class 2 power source Degree of protection IP 20 according to EN 60529 / IEC 60529 4.6 Type label, device labeling (only if cables, plugs and sockets have...
insTallaTion 5.2 Electrical connection → Connect 5-pin spring-type terminal in accordance with configuration. Warning! Color of terminal Description Risk of injury from improper installation. ▶ Installation may be carried out by authorized technicians only and Supply voltage 24 V with the appropriate tools. White CAN H (büS connection) Green...
Page 7
5.3.2 PROFIBUS version → Insert the Ethernet cable into the sockets of the X1 and X2 interfaces. The X1 and X2 interfaces for RJ45 plug-in connectors are equivalent. Configuration of plug-in connector D-Sub, 9-pin note! D-Sub, 9-pin Signal Function Connection 1 and 2 not used To ensure electromagnetic compatibility (EMC) ▶...
sTarT-up opEraTion and funcTion Warning! Warning! ▶ Only adequately trained personnel may operate the system or Risk of injury from improper operation! device. ▶ Only trained and qualified personnel may start up the device or system. Operation using the display is achieved by means of the two arrow keys and the round menu key.
Page 9
The device can be configured on the PC using the Bürkert Communi- settings contrast cator software. A detailed description of the operation and configuration installation → Parameter of the PC software Bürkert Communicator can be found on the website position www.burkert.com → Type 8920. english...
Micro SD card disassEMBly The Micro SD card can be used to save and transfer device-specific values Warning! and user settings to a different device. Risk of injury from improper disassembly. Card holder for Micro SD card ▶ Disassembly may be carried out by authorized technicians only. Carefully pull the cover out of the recess and rotate 1.
PaCkagIng, TRanSPORT DISPOSaL note! Damage in transit due to inadequately protected devices. • Protect the device against moisture and dirt in shock-resistant packaging during transportation. • Observe permitted storage temperature. Incorrect storage may damage the device. • Store the device in a dry and dust-free location. •...