Burkert ME43 Operating Instructions Manual

Burkert ME43 Operating Instructions Manual

Fieldbus gateway büs to industrial ethernet for profibus dpv1, profinet, ethernet/ip, ethercat, modbus tcp, cc-link
Hide thumbs Also See for ME43:
Table of Contents

Advertisement

Type ME43
Fieldbus gateway büS to Industrial Ethernet for
PROFIBUS DPV1, PROFINET, EtherNet/IP,
EtherCAT, Modbus TCP, CC-Link,
Operating Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ME43 and is the answer not in the manual?

Questions and answers

Summary of Contents for Burkert ME43

  • Page 1 Type ME43 Fieldbus gateway büS to Industrial Ethernet for PROFIBUS DPV1, PROFINET, EtherNet/IP, EtherCAT, Modbus TCP, CC-Link, Operating Instructions...
  • Page 2 We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. © Bürkert Werke GmbH & Co. KG, 2017 – 2019 Operating Instructions 1905/02_EUen_00810575 / Original DE...
  • Page 3: Table Of Contents

    Type ME43 Fieldbus gateway type ME43 ontents THE OPERATING INSTRUCTIONS ......................6 Symbols ............................6 1.2 Begriffsdefinitionen ........................7 INTENDED USE ............................7 BASIC SAFETY INSTRUCTIONS ......................8 GENERAL INFORMATION ........................9 4.1 Contact address ...........................9 4.2 Warranty ............................9 4.3 Information on the Internet ......................9 PRODUCT DESCRIPTION ........................10 TECHNICAL DATA ..........................11 6.1 Conformity ..........................11 6.2...
  • Page 4 Type ME43 7.4.2 PROFIBUS version .....................17 7.4.3 CC-Link version ......................17 START-UP .............................18 8.1 Safety instructions ........................18 8.2 Base settings ..........................18 8.3 Selecting fieldbus protocol ......................18 8.4 Configuration of the fieldbus gateway ..................19 8.4.1 Preparing to configure the fieldbus gateway ..............19 8.4.2 Methods for generating a Gateway configuration ............19 8.4.3 Maximum number of data values (objects) ..............20 8.4.4 General settings for the Gateway configuration ............20 8.4.5...
  • Page 5 WEB SERVER ............................47 11.4.1 Connection to the web server ..................47 11.4.2 Access to the web server ...................47 11.4.3 Configuring Ethernet device ..................48 OTHER SETTING OPTIONS .........................50 12.1 Settings on the display of the fieldbus gateway ME43 ............50 12.2 Settings using the PC software “Bürkert Communicator” ............51 12.2.1 f(x) configuration ......................51 12.2.2 Overview of device-specific setting options that can be adjusted using Bürkert Communicator ....................51 MAINTENANCE ............................57 13.1 Safety instructions for maintenance ..................57 13.2 Replacement of the fieldbus gateway ME43 ................57...
  • Page 6: The Operating Instructions

    Type ME43 The operating instructions THE OPERATING INSTRUCTIONS The operating instructions describe the entire life cycle of the device. Keep these instructions ready to hand at the operation site. Important safety information! ▶ Carefully read these instructions. ▶ Observe in particular the safety instructions, intended use and operating conditions.
  • Page 7: Begriffsdefinitionen

    The operating instructions Begriffsdefinitionen Definition of the terms used in these instructions. • Device: the term “Device” stands for the following device types: ME43 • Ex area: the term “Ex area” stands for potentially explosive atmosphere • Ex approval: the term “Ex approval” stands for approval in the potentially explosive atmosphere •...
  • Page 8: Basic Safety Instructions

    Type ME43 Basic safety instructions BASIC SAFETY INSTRUCTIONS These safety instructions do not consider any contingencies or incidents which occur during installation, operation and maintenance. The operator is responsible for observing the location-specific safety regulations, also with reference to the personnel. General hazardous situations. To prevent injury, ensure the following: ▶ Operate the device only in perfect condition and in accordance with the operating instructions.
  • Page 9: General Information

    Type ME43 General information GENERAL INFORMATION Contact address Germany Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940 - 10-91 111 Fax + 49 (0) 7940 - 10-91 448 Email: info@burkert.com International You can find the contact addresses on the internet at: www.burkert.com Warranty The warranty is only valid if the device is used as intended in accordance with the specified application conditions.
  • Page 10: Product Description

    Application area: Switch the process values between the devices of fieldbus 1 and fieldbus 2. Device type Fieldbus 1 Fieldbus 2 ME43 büS PROFINET ME43 büS EtherNet/IP ME43 büS Modbus TCP ME43 büS PROFIBUS DPV1 ME43 büS CC-LINK ME43 büS EtherCAT Table 1: Type ME43 application area The Bürkert Communicator PC software is required to configure the fieldbus gateway. The Bürkert Communicator PC software can be downloaded free of charge from the Bürkert website. In addition to the PC software, the USB-büS-interface set 1, available as an accessory, is required. See chapter “15 Accessories”, page 64. english...
  • Page 11: Technical Data

    Permitted ambient temperature range. -20 °C to +60 °C Operating altitude: up to 2000 m above sea level Mechanical data Dimensions: Refer to data sheet for Type ME43 Housing material: Polycarbonate Electrical data Supply voltage: 24 V ±10 % - residual ripple 10% Power consumption <...
  • Page 12: Type Label, Device Labeling

    Type ME43 Technical data Type label, device labeling Identification number of the device Type Serial number ID: 00307390 S/N: 001001 Type: ME43 W1XXXX QR code (link for further information Manufacture code to the device) CE mark Permitted ambient temperature -20 °C...+60 °C range Supply voltage,...
  • Page 13: Profibus Dpv1 Specifications

    Type ME43 Technical data Transmission speed 10 and 100 Mbit/s Duplex transmission Half Duplex, full Duplex, autonegotiation MDI modes MDI, MDI-X, Auto-MDIX Data transport layer Ethernet II, IEEE 802.3 Address Conflict Detection (ACD) supported DLR (ring topology) supported Integrated switch supported CIP Reset services...
  • Page 14: Cc-Link Specifications

    Type ME43 Technical data CC-Link specifications Features Remote I/O Station only I/O points Remote Device Station i/O points and Words Configurable number of occupied stations 1...4 Configurable number of extension cycles 1, 2, 4, or 8 Supported protocols CC-Link version 2.0 CC-Link version 1.11 CC-Link version 2.0 Number of stations...
  • Page 15: Installation

    Type ME43 Installation INSTALLATION Safety instructions WARNING! Risk of injury from improper installation. ▶ Installation may be carried out by authorized technicians only and with the appropriate tools. ▶ Secure system against unintentional activation. ▶ Following installation, ensure a controlled restart. Mounting on standard rail...
  • Page 16: Electrical Connection

    Type ME43 Installation Electrical connection → Connect 5-pin spring-type terminal in accordance with configuration. Configuration of 5-pin spring-type terminal Connector view Color of terminal Description Supply voltage 24 V White CAN H (büS connection) Green Shielding Blue CAN L (büS connection) Black Table 2: Configuration of 5-pin spring-type terminal Establishing connection to fieldbus 7.4.1 Industrial Ethernet →...
  • Page 17: Profibus Version

    Type ME43 Installation 7.4.2 PROFIBUS version Configuration of plug-in connector D-Sub, 9-pin D-Sub, 9-pin Pin Signal Function Connection not used not used RxD/TxD-P Data line P (B conductor) Mandatory CNTR-P Repeater directional control Optional DGND Ground for data signals and VP Mandatory +5 V supply for bus terminating Optional resistor not used RxD/TxD-N Data line N (A conductor) Mandatory not unsed Figure 4: PROFIBUS, Configuration of plug-in connector D-Sub, 9-pin 7.4.3...
  • Page 18: Start-Up

    Type ME43 Start-up START-UP Safety instructions WARNING! Risk of injury from improper operation! ▶ Before start-up, it must be ensured that the operating personnel are aware of and fully understand the contents of the operating instructions. ▶ Note the safety instructions and intended use. ▶ Only trained and qualified personnel may start up the device or system.
  • Page 19: Configuration Of The Fieldbus Gateway

    Type ME43 Start-up Configuration of the fieldbus gateway The “Bürkert Communicator” PC software and the büS stick, which is available as an accessory, are required for configuration, see chapter “15 Accessories”. The “Bürkert Communicator” software and a general description of it are available on the Bürkert homepage.
  • Page 20: Maximum Number Of Data Values (Objects)

    1024 EtherNet/IP 1008 Modbus TCP 2048 EtherCAT 1024 (ME43 until A.03.02.00) EtherCAT 1024 (ME43 from A.7.5) Table 3: Maximum number of data values 8.4.4 General settings for the Gateway configuration Procedure in the Bürkert Communicator: → Select Industrial communication. → Parameter. → Select Gateway configuration → Create a gateway configuration.
  • Page 21 Type ME43 Start-up Creation of a gateway configuration General settings General device settings Information for inputting see Product code 1296380467 “Table 4: Gateway configuration; Product family Gateway input fields for “General device settings””, page 21 Product name ME43 Description Gateway_ME43_bueS Default network settings IP address of gateway 192.168.0.100...
  • Page 22: Declaring Inputs And Outputs For The Gateway Configuration

    Type ME43 Start-up 8.4.5 Declaring inputs and outputs for the Gateway configuration Create a gateway configuration Declare inputs and outputs Groups / Devices – Products – Electromotive Valves 0030739000000001 332x E_Process_Valve 336x E_Process_Valve Inputs and outputs 328x Motor Control Valve...
  • Page 23 Type ME43 Start-up Adding products: → Add products by drag-and-drop or double-clicking. Values for declaring inputs and outputs have been predefined in the Add device(s) dialogue box. Add device(s) Settings Values per device Device name (prefix for all value names) Count SP_IO Max. possible number of inputs PV_IO Max. possible number of outputs CMD_IO XCO_DO1 Device configuration XCO_DO2...
  • Page 24 Type ME43 Start-up Contextualized definition of value: Input values Icon: Input values are values which come from the büS participant and are read by the PLC (büS device → fieldbus gateway → PLC) Output values Icon: O Output values are values which are written from the PLC to the büS participant/fieldbus gateway. Output value Continued output data Input value büS device Input value...
  • Page 25: Fieldbus-Specific Address Mapping

    Type ME43 Start-up 8.4.6 Fieldbus-specific address mapping → Check editable fields and complete if necessary. The protocol-specific settings are explained in the following screenshots (“Figure 11” to “Figure 15”). → Select Next. If multiple protocols are selected the corresponding protocol-specific configuration pages then appear (see “Figure 6: Configuration, select target protocol”). Adress mapping for EtherNet/IP: Create a gateway configuration EtherNet/IP settings EthernetIP Data Major Revision Minor Revision Order number EtherNet/IP-EDS revision EtherNet/IP product type Generic Device,keyable (43)
  • Page 26 Type ME43 Start-up Adress mapping for PROFINET: Create a gateway configuration Profinet Header Info Main Family Gateway Information Gateway_ME43_bueS Device ID 0x23 Device Access Point Info Advanced Modul ID Minimum cycle time of the gateway 0x100 Hardware version Software version A.01.01.00 580515 Maximum input lenght...
  • Page 27 Type ME43 Start-up Adress mapping for ModbusTCP: Create a gateway configuration Modbus TCP settings Bus Ident Data Device Name: MEX3 MajorMinorRev Addressing Automatic Modbus-TCP addressing Use Modbus FC03 where possible Start address 0 Start Reset device Coil/Register addressing Start address 1 Cyclic Name...
  • Page 28 Type ME43 Start-up Adress mapping for EtherCAT: Create a gateway configuration EtherCAT EtherCAT data EtherCAT product code #xFDF9 Product code of the EtherCAT device, has to be a number, e.g. 12345678 EtherCAT revision EtherCAT revision of the device. Has to be a 8-digit hex-number and start with #x,...
  • Page 29 Type ME43 Start-up Adress mapping for CC-Link Create a gateway configuration CC-Link gui.gateway.CC-Linkdata 2 Station & Estension Cycle: SINGLE gui.gateway.cclinkstationcycles Addressing Automatic CC-Link addressing Start Reset device Cyclic Name Index SubIndex Startadresse EVA_POS 0x2540 0x01 0x000 EVA_NamurStatus 0x2541 0x01 0x00C EVA_CMDdigital 0x2500 0x01...
  • Page 30: Storage And Download Of The Gateway Configuration

    Type ME43 Start-up 8.4.7 Storage and download of the Gateway configuration Creation of a gateway configuration Final settings Select output directory Browse Output directory C:\User\Joe.Bloggs\AppData\Comuni Create new major version Back Cancel Next Figure 16: Selection of output list → In the dialogue box Final settings Select output directory.
  • Page 31: Büs Network Configuration

    Overview of the cyclical and acyclical device values. Table 5: Overview of the files which are generated during the Gateway configuration 8.4.8 büs network configuration A büS network configuration is required to connect other büS devices successfully to the system and to connect to Type ME43. Description see chapter “10 Setting up the büS network” english...
  • Page 32: Protocol Settings For Connecting The Device To The Plc Network

    Type ME43 Start-up Protocol settings for connecting the device to the PLC network The required settings depend on the fieldbus protocol. To ensure that the settings can be made, the fieldbus protocol must be selected in the parameter detailed view: → → Select protocol. Parameter Protocol If devices feature a PROFIBUS interface and CC-Link interface, the fieldbus protocol has been preset at the factory. 8.5.1 Setting the PROFIBUS address PROFIBUS address pre-configured at the factory: 126 The PROFIBUS address can be set on the display of the device or on the PC using the Bürkert Communi- cator PC software.
  • Page 33: Setting The Cc-Link Address

    Type ME43 Start-up 8.5.2 Setting the CC-Link address CC-Link address pre-configured at the factory: 64 The CC-Link address can be set on the display of the device or on the PC using the Bürkert Communicator PC software. The menu for setting the CC-Link address is located in the Parameter detailed view.
  • Page 34: Setting The Ethernet Parameters For Ethernet/Ip, Profinet, Modbus Tcp

    Type ME43 Start-up 8.5.4 Setting the Ethernet parameters for EtherNet/IP, PROFINET, Modbus TCP With Modbus TCP the setting of the Ethernet parameters is mandatory. The EtherNet parameters can be set on the display of the device or on the PC using the Bürkert Communicator PC software or the Webserver. The menu for setting the EtherNet parameters is located in the Parameter detailed view.
  • Page 35: Operation

    Card holder for Micro SD card Figure 17: Overview of the operating elements Operation of Type ME43 using the display Operation using the display is achieved by means of the two arrow keys and the round menu key. Opening the main menu: →...
  • Page 36: Description Of The Keys

    Type ME43 Operation 9.3.1 Description of the keys Element Description Page down through menu Down arrow Decrease numerical values. Hold down arrow key to run through quickly. Page up through menu Up arrow key Increase numerical values. Hold down arrow key to run through quickly.
  • Page 37: Operation Of Type Me43 Using The "Bürkert Communicator" Software

    Type ME43 Operation Operation of Type ME43 using the “Bürkert Communicator” software The device can be configured on the PC using the “Bürkert Communicator” software. The PC software “Bürkert Communicator” can be downloaded free of charge from the Bürkert website. In addition to the software, the USB büS interface set 1, available as an accessory, is required. This chapter only describes the fundamental handling of Bürkert Communicator. A detailed description of the operation and configuration of the PC software “Bürkert Communicator” can be found on the website www. burkert.com → Type 8920. 9.4.1 Bürkert Communicator user interface...
  • Page 38: Establishing A Connection Between The Device And Bürkert Communicator

    Type ME43 Operation 9.4.2 Establishing a connection between the device and Bürkert Communicator The Bürkert Communicator can be connected to the device via a büs network or with the büS stick. → Install the Bürkert Communicator software on the PC.
  • Page 39: Importing And Saving Data Using The Micro Sd Card

    Type ME43 Operation Importing and saving data using the Micro SD card The Micro SD card can be used to save and transfer device-specific values and user settings to a different device. The Micro SD card is not suitable for backups. If the Micro SD card of the device is re-inserted at a later date, the most recently saved data is not restored. The function of the Micro SD card is limited to exchanging data.
  • Page 40 Type ME43 Operation Replacing the Micro SD card Card holder for Micro SD card Cover Figure 19: Replacing the Micro SD card; fieldbus gateway ME43 NOTE! Do not remove the SD card while the supply voltage is applied. If the SD card is removed while the supply voltage is applied, data may be lost and the SD card may be damaged. The SD card can be inserted while the supply voltage is applied. A restart is required to ensure that the device detects the SD card.
  • Page 41: Display Elements Of The Type Me43

    Type ME43 Operation Display elements of the Type ME43 LEDs for network connection to the Industrial Ethernet (not present with Display PROFIBUS version and CC-Link version) Status LED for indicating device status Link LED (yellow) RJ45 Link/Act LED (green) Figure 20: Overview of the display elements...
  • Page 42: Led For Indicating Device Status

    Type ME43 Operation LED for indicating device status The LED that indicates the device status changes color and status in accordance with NAMUR NE 107. If several device statuses exist simultaneously, the device status with the highest priority is displayed. The priority is determined by the severity of the deviation from standard operation (red = failure = highest priority).
  • Page 43: Setting Up The Büs Network

    Type ME43 Setting up the büS network SETTING UP THE büS NETWORK 10.1 Conversion Industrial Ethernet to büS The function of the fieldbus gateway is to convert the process values between an Industrial-Ethernet PLC and büS devices. For this, the fieldbus gateway ME43 must be configured and parameterized. 10.2 Theoretical principles for the selection of büS devices and process values Select the büS devices that are to communicate with the PLC via the fieldbus gateway ME43: Fieldbus gateway büS device 1 büS device 2 Figure 21: Configuration; selection of the büS devices that are to communicate with the PLC Select which process values are to be converted from “Industrial Ethernet” to “büS”:...
  • Page 44 Type ME43 Setting up the büS network Define the direction for transmission of the process values (from/to PLC, from/to büS device): The direction is assigned from the perspective of the fieldbus gateway ME43 in the fieldbus büS. Example: - The set-point values of a büS device are the output values of the fieldbus gateway ME43. - The actual values of a büS device are the input values of the fieldbus gateway ME43. Process output values of the PLC are received by the fieldbus gateway ME43 as process input values via Industrial Ethernet. These process input values are converted and provided as process output values via büS. Conversely, process output values of the büS device are received as büS input values. These process input values are converted and output as process output values via Industrial Ethernet.
  • Page 45: Configuration Of The Büs Network

    Type ME43 Setting up the büS network 10.3 Configuration of the büS network → Establish the connection with the Bürkert Communicator PC software. See chapter “9.4.2 Establishing a connection between the device and Bürkert Communicator” Procedure in Bürkert Communicator: → büS Select in the navigation area. → Select detailed view büS-Map . COMMUNICATOR Edit...
  • Page 46: Download Gateway Configuration File For Device Configuration

    Type ME43 Setting up the büS network 10.4 Download gateway configuration file for device configuration If, for instance, a configuration file exists from a previous project, the device can be directly configured with it. → Establish the connection with the Bürkert Communicator PC software. See chapter “9.4.2 Establishing a connection between the device and Bürkert Communicator” Procedure in Bürkert Communicator: → Select Gateway ME43 in the navigation area. To open the configuration areas, click on +. → Select Industrial communication.
  • Page 47: Web Server

    Type ME43 Web server WEB SERVER The configuration of the Ethernet participant, required to connect to the network, can be run with a Webserver, the Bürkert Communicator or on the display. 11.4.1 Connection to the web server → Setting IP address in the network card of the PC. IP address: 192.168.0.xxx For xxx enter any numerical value except 100 (Ethernet device is delivered with 100 occupied by IP address).
  • Page 48: Configuring Ethernet Device

    Type ME43 Web server With EtherNet/IP, it is also possible to set DHCP or BOOTP (NOT standard). The IP address is acquired from a DHCP server. → Open an Internet browser. → Input Default IP 192.168.0.100. (For Ethernet/IP devices the IP address is assigned via a DHCP server. If no assignment occurs within 1 minute via DHCP, the device uses the Default IP 192.168.0.100.)
  • Page 49 Type ME43 Web server Configuration: → Input device name and IP address for the Ethernet device. The device name (DNS-compatible name) will be used later for project planning (e.g. in STEP 7). → Activate with Commit changes. To accept the changed PROFINET parameters, the voltage must be reset in the Ethernet device.
  • Page 50: Other Setting Options

    IComm vers. IComm version is displayed DEVReplace can be used in conjunction with configuration provider. Table 9: Setting options on the display of the fieldbus gateway ME43 1) Only for PROFIBUS DPV1. 2) Only for CC-Link. 3) Only for EtherNet/IP. 4) Only for PROFINET, EtherNet/IP and Modbus TCP.
  • Page 51: Settings Using The Pc Software "Bürkert Communicator

    12.2.2 Overview of device-specific setting options that can be adjusted using Bürkert Communicator The list of setting options shown below only includes the device-specific options for the fieldbus gateway ME43 and does not include the description of the PC software Bürkert Communicator. A detailed description of the operation and configuration of the PC software “Bürkert Communi- cator” can be found on the website www.burkert.com → Type 8920. Bürkert Communicator: Industrial Communication configuration area Detailed view...
  • Page 52 Type ME43 Other setting options Bürkert Communicator: Industrial Communication configuration area Detailed view Setting Parameter Select Protocol For a description see chapter “Setting up the büS network”. Protocol settings Set PROFIBUS address. Set baud rate Change baud rate. for PROFIBUS DPV1 Advanced Set Internal cycle time. settings Set Control mode settings. Protocol firmware update Protocol settings Specify Assistant for checking input and start conditions for büS...
  • Page 53 Type ME43 Other setting options Bürkert Communicator: Industrial Communication configuration area Detailed view Setting Parameter Protocol settings Specify Assistant for checking input and start conditions for büS communication. for Modbus TCP Set Static IP address. Set Network mask. Set Default gateway. MAC address is displayed. Advanced settings Set Internal cycle time. Activate Communication Timeout. Set Control mode settings.
  • Page 54 Type ME43 Other setting options Bürkert Communicator: General settings configuration area Detailed view Menu Configuration of the büS interface. Parameter büS Assign for display and Bürkert Communicator. Displayed name Specify location displayed for the device. Location Description Enter description text for tooltips. Advanced Unique device name For partner allocation. Specify Baud rate. Specify CANopen address.
  • Page 55 Type ME43 Other setting options Bürkert Communicator: General settings configuration area Detailed view Menu In these menus Diagnostics Device status Operating duration the current Device temperature values are dis- Supply voltage played, not set. Voltage drops Number of voltage drops since restart. Min./Max. values Max. temperature Min. temperature Max. supply voltage Min. supply voltage Device boot counter Transferable memory status Current system time Battery voltage Number of received errors since büS status...
  • Page 56 Type ME43 Other setting options Bürkert Communicator: General settings configuration area Detailed view Menu Is only displayed if a name In these menus Maintenance Device information Displayed name has been input in the menu of the same the current values name in the parameters detailed view. are displayed, not set.
  • Page 57: Maintenance

    ▶ Maintenance may be carried out only by trained technicians and with the appropriate tools. ▶ Secure system against unintentional activation. ▶ Following maintenance, ensure a controlled restart. 13.2 Replacement of the fieldbus gateway ME43 Procedure: 1. Switch off supply voltage. 2. Remove 5-pin spring-type terminal. Figure 30: Remove 5-pin spring-type terminal 3. R emove Ethernet cable from the X2 and X2 interfaces.
  • Page 58 Type ME43 Maintenance 5. Remove the Micro SD card Card holder for Micro SD card Cover Figure 32: Replacing the Micro SD card; fieldbus gateway ME43 → Carefully pull the cover out of the recess. → Rotate the cover upwards to the left. →...
  • Page 59: Troubleshooting

    Type ME43 Troubleshooting TROUBLESHOOTING Problem Possible cause Procedure The NAMUR-LED goes out The power supply collapses peri- Use power supply with adequate periodically. odically – the device performs a power. reset each time. The voltage drop in the connection Increase cable cross-section.
  • Page 60: Description Of The Error Codes

    Type ME43 Troubleshooting 14.1 Description of the error codes Error code Description Overload detected. Overvoltage detected. Undervoltage detected. Voltage is above the warning limit. Voltage is below the warning limit. Battery voltage is below the warning limit. Voltage drop detected. Overtemperature detected.
  • Page 61 Type ME43 Troubleshooting Error code Description 33/13 Output value simulation for at least one value active. 33/14 Demo mode activated. 33/32768 1 Status message is pending. 35/1 EERPROM error has been detected. 35/2 At least 1 persistent memory cannot be used.
  • Page 62 Type ME43 Troubleshooting Error code Description 51/205 Error while config connections, more than 5 connections. 51/206 Wrong PROFIBUS address valid addresses are 1 - 126. 51/207 Wrong CC-Link address valid addresses are 1 - 64. 51/208 Wrong CC-Link baud rate. 51/300 Fieldbus master is running in stop mode.
  • Page 63: Status Indicators And Action To Be Taken

    Type ME43 Troubleshooting 14.2 Status indicators and action to be taken Status LED indicators Description Procedure based on NAMUR NE 107 No color No power is supplied to the device. Connect device to power supply. Flashing rapidly The device was selected using the De-select the device using the (applies to all colors) “Bürkert Communicator”...
  • Page 64: Accessories

    Type ME43 Accessories ACCESSORIES CAUTION! Risk of injury and/or damage due to the use of incorrect parts! Incorrect accessories and unsuitable spare parts may cause injuries and damage the device and its environment. ▶ Use original accessories and original spare parts from Bürkert only. Accessories Order number USB-büS-Interface set 1 (including power supply unit) and “Bürkert Communicator”...
  • Page 65: Disassembly

    Type ME43 Disassembly DISASSEMBLY WARNING! Risk of injury from improper disassembly. ▶ Disassembly may be carried out by authorized technicians only. 1. Switch off supply voltage 2. Remove 5-pin spring-type terminal. Figure 34: Remove 5-pin spring-type terminal 3. R emove Ethernet cable from the X2 and X2 interfaces. For the PROFIBUS version and CC-Link version: Remove plug-in connector D-Sub, 9-pin. 4. Remove the device from the standard rail Figure 35: Remove the device from the standard rail → Push the device upwards and detach it from the upper guide of the standard rail...
  • Page 66: Packaging, Transport

    Type ME43 Packaging, transport PACKAGING, TRANSPORT NOTE! Damage in transit due to inadequately protected devices. • Protect the device against moisture and dirt in shock-resistant packaging during transportation. • Observe permitted storage temperature. STORAGE NOTE! Incorrect storage may damage the device. • Store the device in a dry and dust-free location. • Storage temperature: -30 °C to +80 °C.
  • Page 67 www.burkert.com...

Table of Contents