Vicon V1411X-DVC Installation & Operation Manual

Vicon V1411X-DVC Installation & Operation Manual

Variable speed keypad
Hide thumbs Also See for V1411X-DVC:

Advertisement

Quick Links

XX074
V1411X-DVC
Variable Speed Keypad
Vicon Industries Inc. does not warrant that the functions contained in this
equipment will meet your requirements or that the operation will be entirely
error free or perform precisely as described in the documentation. This
system has not been designed to be used in life-critical situations and
must not be used for this purpose.
Copyright © 2001 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300 INFOFAX: 800-287-1207 WEB: www.vicon-cctv.com
Vicon Part No. 8009-8074-00-00
Rev 101 Section 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V1411X-DVC and is the answer not in the manual?

Questions and answers

Summary of Contents for Vicon V1411X-DVC

  • Page 1 XX074 V1411X-DVC Variable Speed Keypad Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose.
  • Page 2 FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNING This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio and television reception.
  • Page 4: Table Of Contents

    Contents Introduction......................... 1 Configuration & Installation....................1 Keypad Setup........................4 Operation ..........................6 Operating Modes............................6 Alarms ................................6 Auxiliary Function Control ..........................6 Communication Failure ..........................6 Crosspoint Reset ............................7 Lens Operation............................... 7 Presets ................................7 Manual Switching ............................7 Salvos and Tours : V1400 control systems only ..................
  • Page 5 The video product may fall, causing serious injury to a person and serious damage to the video product. Use only with a mounting accessory recommended by Vicon, or sold When the power-supply cord or plug is damaged. with the video product. Any mounting of the video product should follow Vicon’s If liquid has been spilled, or objects have fallen into the video product.
  • Page 6: Introduction

    The V1411X-DVC Variable-Speed Keypad operates as a standalone controller for dome/receivers without the need for matrix switchers or in a multi-keypad installation using a NOVA control system. Compatible with any of Vicon’s NOVA control systems, the V1411X-DVC may also be used with the V1411 series of video switchers with telemetry control.
  • Page 7 UP TO 255 RECEIVER/DOMES The V1411X-DVC is shipped with the appropriate power supply for your installation. For 230 VAC, a 9 VAC power supply is included. A 12 VDC power supply is included for 120 VAC. For illustration purposes, the power supply shown is a desktop version (the 12 VDC power supply actually plugs directly into the wall outlet).
  • Page 8 The V1411X-DVC is shipped with a 9 VAC power supply for 230 VAC units and a 12 VDC power supply for 120 VAC. One power supply is required for each keypad in your system. Only the first keypad shows a power supply in the figure below and the power supply shown is a desktop version (the 12 VDC power supply actually plugs directly into the wall outlet).
  • Page 9: Keypad Setup

    Keypad Setup Note: (For NOVA mode only) Before powering your control system, perform the keypad setup described in this chapter. Make sure to define the keypad baud rate (all keypads in your CCTV system must have the same baud rate) and keypad address (each keypad must have a unique address). After you have set up the keypad completely, power your control system and refer to its documentation to set the Keypad State to Auto in the control system programming menus.
  • Page 10 Pace Factor This applies to NOVA mode at 19,200 baud only. Do not change this setting without direction from Vicon Technical Support. Additional Stops Causes additional stop messages to be sent from the joystick or lens keys when this key is released.
  • Page 11: Operation

    Operation Operating Modes Mode 1 is automatically entered Accessing Operating Modes after power is applied or if the Mode Description keypad is reset. Refer to Normal operating mode PROG PROG Indicators in Display in the Preset Store mode. Set Dwell mode. Technical Information chapter for Press &...
  • Page 12: Crosspoint Reset

    Crosspoint Reset Full System Reset Single Cage Reset For any For V1400 DWELL DWELL control control system: system: Press Press Press Press Lens Operation Controlling the Lens Toggle key to Note that autoiris operation has Toggle key to automatically priority over manual iris control. To LENS CLOSE NEAR...
  • Page 13: Sequential Switching: V1300 And V1344 Control Systems Only

    Sequential Switching: V1300 and V1344 control systems only Starting a Sequence Viewing Monitors in a Sequence Adding Cameras This starts a Press SEQ sequence of to start the cameras that you sequence. have already added. Press Enter camera number Press Press Enter monitor number Press...
  • Page 14: Technical Information

    Technical Information PrePac Model Descriptions Model Number Product Code Input Voltage Power Supply V1411X-DVC 7518 120 VAC 12 VDC at 500 mA; wall mount. V1411X-DVC-230 7518-01 230 VAC 9 VAC at 600 mA; desktop style. Electrical Input Voltage: See PrePac Model Descriptions above. Note that you may also use a 9.5 VAC power supply at 600 mA with 120 VAC units (not included).
  • Page 15: Shipping Instructions

    Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 16 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2288) Infofax: 800-287-1207 Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom 44/(0) 1489/566300 Fax: 44/(0) 1489/566322 Brussels Office Planet II - Unit E...

Table of Contents