READy MTU

5 Technical data

5.1 Product introduction

READy MTU is a one-to-one meter data transmission unit that connects to meters utilizing the Sensus UI1203 Encoded Output
protocol. Data from READy MTU is forwarded to the READy Manager MDM system via Kamstrup's AMI system.

5.2 System overview

READy MTU connects to an encoded output meter and sends data to READy Collector and READy Manager.

5.3 Electrical data

Battery safety:
Fire, explosion and severe burn hazard.
Please follow these guidelines in order to avoid injury to yourself and others:
If not disposed of properly, the battery may cause fire or chemical burn
Do NOT recharge, disassemble, crush, expose to water, heat above 212 °Fahrenheit (100 °Celsius), or
incinerate the battery
Keep away from children
Do not disassemble the product as the IP68 sealing will be void, and do not tamper with the internal battery and
electronics.
Battery
Battery liftetime

5.4 Mechanical data

READy MTU is designed to operate at temperatures of -30 °C...65 °C (-22 °F...149 °F). Using the device outside the
intended operating temperature range may cause deterioration of battery life or in worst case operating failure.
Protection class
Weight
Dimensions
Kamstrup A/S • 55122662_C1_US_06.2020
D-cell battery
Up to 20 years at tBAT < 40 °F
Up to 16 years at tBAT < 55 °F
Up to 8 years at tBAT < 130 °F
IP68 rated (waterproof/submersible)
Approx. 525 g / 1.15 Lbs incl. stub antenna
Ø 91.6 mm x 106 mm (Ø 3.6" x 4.2")
Ø 91.6 mm x 149.8 mm (Ø 3.6" x 5.9") incl. antenna