CPU Fan True Value Table (AC/DC Mode)

Temperature (°C)
Fan on = 40°C; Fan Off = 35°C
Fan on = 55°C; Fan Off = 50°C
Fan on = 65°C; Fan Off = 60°C
Fan on = 75°C; Fan Off = 70°C
Fan on = 90°C; Fan Off = 85°C
Throttling 50%: On =93°C; Off=88°C
OS Shut down: 96°C
H/W Shut down: 100°C

System Memory

Item
Memory controller
Memory size
DIMM socket number
Supports memory size per
socket
Supports maximum memory size
Supports DIMM type
Supports DIMM Speed
Support DIMM voltage
Supports DIMM package

Memory Combinations

Slot 1 (MB)
1024
2048
1-26
Fan Speed (RPM)
3800
4200
4500
5000
95% Duty
Built in at CPU
DDRIII 800/1066 2 GB (N2600 series), 4 GB (N2800 series)
2 socket
2 GB for N2600 series, 4GB for N2800 series
2 GB for N2600 series, 4GB for N2800 series
SDRAM memory interface design
Note: Processor supports up to 800 MHz for N2600
series, 1066 MHz for N2800 series
800/1066 SODIMM
Standard JEDEC 1.5V
Standard JEDEC 204-pin
Slot 2 (MB)
N/A
N/A
Hardware Specifications and Configurations
SPL Spec (dBA)
26
29
31
34
N/A
Specification
Total Memory (MB)
1024
2048