Installation and Operation Manual
FW2700
(CB00003 and CB00013 models)
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOOD STOVE
Safety tested according to ULC S627, UL 737
and UL 1482 Standards by an accredited
laboratory
www.century-heating.com
Stove Builder International Inc.
250, rue de Copenhague, St-Augustin-de-Desmaures
(Quebec) Canada G3A 2H3
After-sale service: 418-908-8002
E-mail: tech@sbi-international.com
This manual is available for free download on the manufacturer's web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
READ AND KEEP THIS MANUAL FOR REFERENCE
45597A
Printed in Canada
09-07-2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FW2700 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Century Heating FW2700

  • Page 1 Installation and Operation Manual FW2700 (CB00003 and CB00013 models) US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD STOVE Safety tested according to ULC S627, UL 737 and UL 1482 Standards by an accredited laboratory www.century-heating.com Stove Builder International Inc. 250, rue de Copenhague, St-Augustin-de-Desmaures...
  • Page 2 Century FW2700 Installation and Operation Manual THANK YOU FOR CHOOSING THIS CENTURY WOOD STOVE As one of North America’s largest and most respected wood stove and fireplace manufacturers, Stove Builder International takes pride in the quality and performance of all its products.
  • Page 3: Table Of Contents

    Century FW2700 Installation and Operation Manual Table of content PART A - OPERATION AND MAINTENANCE ........6 1 Safety Information ................6 2 General Information ................7 Appliance performance ..................7 General Features ....................8 Zone Heating and How to Make it Work for You ..........10 The Benefits of Low Emissions and High Efficiency ..........
  • Page 4 Century FW2700 Installation and Operation Manual Stove Maintenance ....................23 5.1.1 Plated Finish Maintenance ................23 5.1.2 Cleaning Door Glass ..................23 5.1.3 Replacing the Door Gasket ................24 5.1.4 Replacing the Glass Gasket and/or the Glass ..........24 5.1.5 Cleaning and Painting the Stove ...............
  • Page 5 Century FW2700 Installation and Operation Manual Appendix 2: Installation and Use of the Optional Blower and Thermodisc....................42 Appendix 3: Exploded Diagram and Parts List ........44 CENTURY HEATING LIMITED WARRANTY ........ 47...
  • Page 6: Part A - Operation And Maintenance

    Century FW2700 Installation and Operation Manual PART A - OPERATION AND MAINTENANCE Please see Part B for installation instructions. 1 Safety Information • HOT WHILE IN OPERATION, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. GLOVES MAY BE NEEDED FOR STOVE OPERATION.
  • Page 7: General Information

    Century FW2700 Installation and Operation Manual General Information CB00003 FW2700 Wood stove CB00013 FW2700 Wood stove with blower 2.1 Appliance performance Fuel type Dry cordwood Recommended heating area 500 to 1,700 ft2 (46 to 158 m Firebox volume 1.6 ft3 (0.045 m...
  • Page 8: General Features

    Century FW2700 Installation and Operation Manual 2.2 General Features Maximum log length 22 in (559 mm) east-west* Flue outlet diameter 6 in (152 mm) Recommended connector pipe diameter 6 in (152 mm) Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
  • Page 9 Century FW2700 Installation and Operation Manual...
  • Page 10: Zone Heating And How To Make It Work For You

    2.3 Zone Heating and How to Make it Work for You Your new Century FW2700 wood stove is a space heater, which means it is intended to heat the area it is installed in, as well as spaces that connect to that area, although to a lower temperature.
  • Page 11: The Benefits Of Low Emissions And High Efficiency

    Century FW2700 Installation and Operation Manual 2.4 The Benefits of Low Emissions and High Efficiency The low smoke emissions produced by the special features inside the Century FW2700 firebox mean that your household will release up to 90 percent less smoke into the outside environment than if you used an older conventional stove.
  • Page 12: Fuel

    Century FW2700 Installation and Operation Manual 3 Fuel 3.1 Materials That Should Not be Burned • GARBAGE OF ANY KIND, • COAL OR CHARCOAL, • TREATED, PAINTED OR COATED WOOD, • PLYWOOD OR PARTICLE BOARD, • FINE PAPER, COLORED PAPER OR CARDBOARD, •...
  • Page 13: Log Length

    Century FW2700 Installation and Operation Manual 3.2.3 Log Length Logs should be cut about 1” (25 mm) shorter than the firebox so they fit in easily. Pieces that are even slightly too long make loading the stove very difficult. The most common standard length of firewood is 16”...
  • Page 14: How To Dry Firewood

    Century FW2700 Installation and Operation Manual 3.2.5 How to Dry Firewood Firewood that is not dry enough to burn is the cause of most complaints about wood inserts. Continually burning green or unseasoned wood produces more creosote and involves lack of heat and dirty glass door. See Section 5: Maintaining your wood heating system for concerns about creosote.
  • Page 15: Judging Firewood Moisture Content

    Century FW2700 Installation and Operation Manual 3.2.6 Judging Firewood Moisture Content You can find out if some firewood is dry enough to burn by using these guidelines: • cracks form at the ends of logs as they dry • as it dries in the sun, the wood turns from white or cream coloured to grey or yellow, •...
  • Page 16: Operating Your Stove

    Century FW2700 Installation and Operation Manual 4 Operating Your Stove 4.1 The use of a fire screen. This stove has been tested for use with an open door in conjunction with a fire screen (AC01319, sold separately). Make sure the fire screen is properly secured on the stove to avoid any risk of fire.
  • Page 17: Conventional Fire Starting

    Century FW2700 Installation and Operation Manual 4.3.1 Conventional Fire Starting The conventional way to build a wood fire is to bunch up 5 to 10 sheets of plain newspaper and place them in the firebox. Next, place 10 or so pieces of fine kindling on the newspaper.
  • Page 18: Using Fire Starters

    Century FW2700 Installation and Operation Manual 4.3.4 Using Fire Starters Many people like to use commercial fire starters instead of newspaper. Some of these starters are made of sawdust and wax and others are specialized flammable solid chemicals. Follow the package directions for use.
  • Page 19: Ash Removal

    Century FW2700 Installation and Operation Manual 4.4.2 Ash Removal Ash should be removed from the firebox every two or three days of full time heating. Do not let the ash build up in the firebox because it will interfere with proper fire management.
  • Page 20: Turning Down The Air Supply

    Century FW2700 Installation and Operation Manual DO NOT LEAVE THE STOVE UNATTENDED WHILE A NEW LOAD IS BEING FIRED HOT. DO NOT OVERFIRE. When you burn a new load of wood hot to heat up the wood, the stove and the chimney, the result will be a surge of heat from the stove.
  • Page 21 Century FW2700 Installation and Operation Manual 4.4.6.1 Small Fires to Take the Chill Off the House To build a small fire that will produce a low heat output, use small pieces of firewood and load them crisscross in the firebox. The pieces should be only 3” to 4” in diameter. After raking the coals, you can lay two pieces parallel to each other corner to corner in the firebox and lay two more across them in the other direction.
  • Page 22 Century FW2700 Installation and Operation Manual The table below provides a very general indication of the maximum burn cycle times you are likely to experience, based on firebox volume. FIREBOX VOLUME MAXIMUM BURN TIME <1.5 cubic feet 3 to 5 hours 1.5 c.f.
  • Page 23: Maintaining Your Wood Heating System

    Century FW2700 Installation and Operation Manual 5 Maintaining Your Wood Heating System 5.1 Stove Maintenance Your new stove will give many years of reliable service if you use and maintain it correctly. Some of the internal components of the firebox, such as firebricks, baffles and air tubes, will wear over time under intense heat.
  • Page 24: Replacing The Door Gasket

    Century FW2700 Installation and Operation Manual 5.1.3 Replacing the Door Gasket It is important to maintain the gasket in good condition. After a year or more of use, the door gasket will compress and become hard, which may allow air to leak past it. You can test the condition of the door gasket by closing and latching the door on a strip of paper.
  • Page 25: Cleaning And Painting The Stove

    Century FW2700 Installation and Operation Manual The gasket must be centred on the edge of the glass. To do this easily, peel back a section of the paper covering the adhesive and place the gasket on a table with the adhesive side up.
  • Page 26: Chimney And Chimney Connector Maintenance

    Century FW2700 Installation and Operation Manual 5.2 Chimney and Chimney Connector Maintenance 5.2.1 Why Chimney Cleaning is Necessary Wood smoke can condense inside the chimney connector and chimney, forming a combustible deposit called creosote. If creosote is allowed to build up in the venting system it can ignite when a hot fire is burned in the stove and a very hot fire can progress to the top of the chimney.
  • Page 27: Cleaning The Chimney

    Century FW2700 Installation and Operation Manual 5.2.3 Cleaning the Chimney Chimney cleaning can be a difficult and dangerous job. If you don’t have experience cleaning chimneys, you might want to hire a professional chimney sweep to clean and inspect the system for the first time. After...
  • Page 28: Part B - Installation

    SLEEPING ROOM OF A CONVENTIONAL HOME. 6.2 Regulations Covering Stove Installation When installed and operated as described in these instructions, the Century FW2700 wood stove is suitable for use as a freestanding heater in residential installations. In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and the CSA C22.1 Canadian National Electrical Code are to be followed in the...
  • Page 29: Clearances To Combustible Material

    Century FW2700 Installation and Operation Manual 7 Clearances to Combustible Material The clearances shown in this section have been determined by test according to procedures set out in safety standards ULC S627 (Canada), UL1482 (U.S.A.) and UL737 (U.S.A.). When the stove is installed so that its surfaces are at or beyond the minimum clearances specified, combustible surfaces will not overheat under normal and even abnormal operating conditions.
  • Page 30 Century FW2700 Installation and Operation Manual *The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. However, you can install the stove at reduced clearances; follow the instructions in Section 7.4: Reducing Wall and Ceiling Clearances Safely.
  • Page 31: Floor Protector

    Century FW2700 Installation and Operation Manual Clearances to combustible materials and floor protection 7.3 Floor protector Your stove has been conceived to prevent the floor from overheating. However, it must be placed on a noncombustible surface to protect the floor from hot embers that could fall from the stove while loading or cleaning.
  • Page 32: Reducing Wall And Ceiling Clearances Safely

    Century FW2700 Installation and Operation Manual 7.4 Reducing Wall and Ceiling Clearances Safely It is often desirable to reduce minimum installation clearances by placing the stove closer to walls so the installation takes up less floor space. You can safely reduce the minimum...
  • Page 33 Century FW2700 Installation and Operation Manual Clearances for shield construction...
  • Page 34: Table Of Clearance Reduction Percentages

    Century FW2700 Installation and Operation Manual 7.4.2 Table of Clearance Reduction Percentages Clearances may be reduced by these percentages Sides Top % Type of shield and rear % (ceiling) Can/US Can/US min. min. Sheet metal, a minimum of 24 gauge (0.61 mm) in thickness ,...
  • Page 35: The Venting System

    Century FW2700 Installation and Operation Manual 8 The Venting System 8.1 General The venting system, made up of the chimney and the connecting pipe between the stove and the chimney, acts as the engine that drives your wood heating system. Even the best stove will not function safely and efficiently as intended if it is not connected to a suitable chimney.
  • Page 36: Masonry Chimneys

    Century FW2700 Installation and Operation Manual 8.2.2 Masonry Chimneys The stove may also be connected to a masonry chimney, provided chimney complies with the construction rules found in the building code enforced locally. The chimney must have either a clay liner or a suitably listed stainless steel liner.
  • Page 37: The Relationship Between The Chimney And The House

    Century FW2700 Installation and Operation Manual 8.4 The Relationship Between the Chimney and the House Because the venting system is the engine that drives the wood heating system, it must have the right characteristics. The signs of bad system design are cold backdrafting when there is no fire in the stove, slow kindling of new fires, and smoke roll-out when the door is opened for loading.
  • Page 38: Supply Of Combustion Air

    Century FW2700 Installation and Operation Manual There are two reasons why the chimney in the house at right will cold backdraft when it is cold outside and there is no fire burning in the stove. First, the chimney runs up the outside of the...
  • Page 39: Installing The Chimney Connector

    Century FW2700 Installation and Operation Manual 8.6 Installing the Chimney Connector The chimney connector is the single or double wall pipe installed between the stove flue collar and the chimney breech. Single wall pipe components are available from most hardware and building supply stores. These components are not usually tested to a particular standard and certified as compliant.
  • Page 40 Century FW2700 Installation and Operation Manual The rules below are based on those found in the CSA B365 installation code. Please carefully follow these installation instruction rules, or those enforced where you live. • Maximum overall length of straight pipe: 3 m (10 ft.) including elbows.
  • Page 41: Appendix 1: Installing The Optional Fire Screen (Ac01319)

    Century FW2700 Installation and Operation Manual Appendix 1: Installing the Optional Fire Screen (AC01319) Open the door. Hold the fire screen by the two handles and bring it close to the door opening. Lean the upper part of the fire...
  • Page 42 Century FW2700 Installation and Operation Manual Appendix 2: Installation and Use of the Optional Blower and Thermodisc An optional blower can be installed on the back of the stove model CB00003 (included on model CB00013) to increase the flow of air past heat exchange surfaces and to help circulate warm air in the room.
  • Page 43 Century FW2700 Installation and Operation Manual The blower has a rheostat. See the illustration on the right to identify the different adjustment positions; either from high (HI) to low (LO) or closed (OFF). When using the optional blower, allow the stove to reach operating temperature (approximately one hour), before turning it on.
  • Page 44 Century FW2700 Installation and Operation Manual Appendix 3: Exploded Diagram and Parts List...
  • Page 45 Century FW2700 Installation and Operation Manual IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your stove, please provide the model number and the serial number. We reserve the right to change parts due to technology upgrade or availability. Contact an authorized dealer to obtain any of these parts.
  • Page 46 Century FW2700 Installation and Operation Manual Item Description 35 PL36021 2 1/8" X 9" X 1 1/4'' REFRACTORY BRICK 36 PL36049 4 1/2" X 4 1/2'' X 1 1/4'' REFRACTORY BRICK 37 29010 4 1/2" X 9" X 1 1/4" REFRACTORY BRICK 38 PL36046 4 1/2"...
  • Page 47 Century FW2700 Installation and Operation Manual CENTURY HEATING LIMITED WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to your CENTURY dealer.

This manual is also suitable for:

Cb00013Cb00003

Table of Contents