Page 1
MUST BE CARRIED OUT BY AN AUTHORIZED PERSON. ANY QUERIES SHOULD BE FORWARDED TO: MANUFACTURER: A’VARD INDUSTRIES P/L. ADDRESS: 58-60 Quantum Close, South Dandenong, Victoria 3175, Australia. TEL: 61 3 9799 9660 Email: info@goldlinecorp.com.au WEBSITE: www.goldlinecor .com.au Goldline N17- manual Oct. 2017...
Page 2
Cut-Out (in mm) Model : GL3BZNG / GL3BZLPG / GL3BZNG-CAST / GL3BZLPG-CAST Diagram A Diagram B GL3WZNG / GL3WZLPG / GL3WZNG-CAST / GL3WZLPG-CAST GL3SSNG / GL3SSLPG / GL3SSNG-CAST / GL3SSLPG-CAST Tray Dimensions (in mm) Cut-Out (in mm) Goldline N12- manual-ULPG June 2016...
Page 3
GL4SSNG / GL4SSLPG / GL4SSNG-CAST / GL4SSLPG-CAST Tray Dimensions (in mm) Cut-Out (in mm) Model : GL704BZNG / GL704BZLPG / GL704BZNG-CAST / GL704BZLPG-CAST Diagram A Diagram B GL704WZNG / GL704WZLPG / GL704WZNG-CAST / GL704WZLPG-CAST Tray Dimensions (in mm) Cut-Out (in mm) Goldline N17- manual Oct. 2017...
The gas connection to the regulator is 1/2” BSP. Please ensure gas supply line to the appliance is of adequate length to allow sufficient withdrawal of appliance for service or disconnection. The connection must be annealed copper pipe or flexible hose (if permissible by local aythority). Goldline N12- manual-ULPG June 2016...
Page 5
- Disconnect gauge and replace test point screw. 9 . Test the appliance - Depress each control knob and turn to full flame setting. - The burner will ignite. Adjust control knob to desired setting. Normally, no adjustment should be necessary. Goldline N17- manual Oct. 2017...
Page 6
- DO NOT TOUCH SPARK IGNITOR WHILE LIGHTING THE BURNER. - WHEN THE APPLIANCE IS INSTALLED IN A MARINE CRAFT OR IN A CARAVAN, IT SHALL NOT BE USED AS A SPACE HEATER. - DO NOT MODIFY THIS APPLIANCE. Goldline N12- manual-ULPG June 2016...
4-5mm 2. Check connection to ignitor, replace if faulty. if any problem cannot be rectified please contact the agent in your state or the gas supply authority service department or contact the product manufacturer. Goldline N17- manual Oct. 2017...
BATTERY REPLACEMENT (applicable to battery ignition model) Open the battery holder cover flap 2. Remove old battery 3. Replace with new 1.5 Volt “D” size battery noting correct polarity Close cover flap Goldline N12- manual-ULPG June 2016...
Check the burner port regularly for blockage especially if there is occurrence of spillage and clean them if necessary. MAINTENANCE SCHEDULE It is recommended that to have the units serviced by an authorized person at least once a year. Goldline N17- manual Oct. 2017...
State should be consulted. Note: Should you still experience difficulties with your Goldline cook top please contact the manufacturer at the address and phone number provided in this manual Goldline N12- manual-ULPG June 2016...
Page 11
SPARE PARTS SERVICE CONTACT NUMBERS: For spare part and technical support enquires please call MANUFACTURER: A’VARD INDUSTRIES P/L. ADDRESS: 58-60 Quantum Close, South Dandenong, Victoria 3175, Australia. TEL: 61 3 9799 9660 WEBSITE: www.goldlinecorp.com.au e-mail: info@goldlinecorp.com.au Goldline N17- manual Oct. 2017...
Need help?
Do you have a question about the GL301BZNG and is the answer not in the manual?