REPA MILLENNIUM V8 BASIC PLUS Instruction Manual page 11

Water softener system with valve 69p1/69p3, models: crono - volume
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
With the buttons
Press again the button
flashing.
With the buttons
Confirm with the button
3) HOW TO SET REGENERATION FREQUENCY
Press the arrow buttons
Press the button
. A wrench symbol will light up on the keypad
Press the button
3 times. The digits 1 - 03 will appear on the display.
warning
NOTE
N.B: Note that the 2 rightmost digits might have already been changed with a previous setting.
Press the button
. The two rightmost digits 1 - 03 will start flashing on the display.
warning
NOTE
N.B: This means that a regeneration process will occur every 3 days.
Use one of the arrow buttons
regeneration processes.
Press the button
to confirm and wait for 60 seconds, until a beep sound signals the locking of the keypad.
The regeneration frequency has now been set.
set the desired regeneration hours.
and the second 2 digits of the display representing the regeneration minutes 02 - 00 will start
set the desired regeneration minutes.
and wait 60 seconds until you hear the sound of the beep and it indicates the key pad is locked.
simultaneously and hold for 5 seconds. A beep sound will signal the unlocking of the keypad.
to change the interval by inputting how many days should pass between two
.