Chapter 1. Specification; Specification - IVT AY-XP12JHR-N Service Manual

Split type room air conditioners
Table of Contents

Advertisement

AYXP12JHRN
AYXP12JHRN
CHAPTER 1.

SPECIFICATION

[1] SPECIFICATION
1. AY-XP12JHR-N – AE-X12JR-N
ITEMS
Rated cooling capacity (Min– Max.)
Rated heating capacity (Min–Max.)
Moisture removal (at cooling)
Electrical data
Phase
Rated frequency
Rated voltage
Rated current ☆
Cool
(Min - Max.)
Heat
Rated input ☆
Cool
Heat
(Min - Max.)
Power factor ☆
Cool
Heat
Maximum operating current
Compressor
Type
Model
Oil charge
Refrigerant system
Evaporator
Condenser
Control
Refrigerant (R410A)
De-lce system
Noise level
High
(at cooling/heating)
Low
Soft
Fan system
Drive
Air flow quantity
High
(at cooling/heating)
Low
Soft
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Drain piping mm
Others
Safety device
Air filters
Net dimensions
Width
Height
Depth
Net weight
NOTE: The conditions of star"✩" marked item are based on 'EN14511'.
Service Manual
MODEL
INDOOR UNIT
AY-XP12JHR-N
kW
3.5 (0.9 - 4.0)
kW
4.6 (0.9 - 6.5)
Liters/h
Single
Hz
V
220-240
A
4.2 (0.9 - 5.7 )
A
5.0( 0.9 - 7.4 )
W
920 (200- 1250)
W
1075 (160 - 1700)
%
%
A
Hermetically sealed rotary type
DA111A1F22F
450cc (Ester oil VG74)
Louver Fin and Grooved tube type
Corrugate Fin and Grooved tube type
Expansion valve
1140g
Micro computer controled reversed systems
dB(A)
40
dB(A)
dB(A)
27
Direct drive
m3/min.
9.3
m3/min.
7.6
m3/min.
5.2
Cross flow fan
Flare type
3/8", 1/4"
O.D φ18
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Polypropylene net (Washable)
mm
790
mm
260
mm
290
kg
11
1 – 1
OUTDOOR UNIT
AE-X12JR-N
1.2
50
95
93
9.6
47
32.2
Propeller fan
780
540
265
36

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae-x12jr-n

Table of Contents