Nominal Data; Technical Description; Mounting Data; Transport And Storage Conditions - ebm-papst A2S130-AA03-22 Operating Instructions Manual

Table of Contents

Advertisement

A2S130-AA03-22

3.2 Nominal data

Motor
M2S052-CA
Phase
1~
Nominal voltage / VAC
230
Frequency / Hz
50
Method of obtaining
fa
data
Valid for approval/
CE
standard
-1
Speed (rpm) / min
2800
Power consumption / W
45
Current draw / A
0.31
Max. back pressure / Pa
80
Min. ambient
-25
temperature / °C
Max. ambient
50
temperature / °C
Starting current / A
0.45
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change

3.3 Technical description

Weight
0.9 kg
Size
130 mm
Motor size
52
Rotor surface
Rotor open, painted black
Blade material
Sheet steel, painted black
Number of blades
7
Airflow direction
V
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP20
Insulation class
"B"
Moisture (F) /
H1
Environmental (H)
protection class
Installation position
Any
Condensation
None, open rotor
drainage holes
Mode
S1
Motor bearing
Ball bearing
Touch current
< 0.75 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Item no. 13144-5-9970 · ENU · Change 220349 · Approved 2021-10-25 · Page 5 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Protection class
assignment
1~
230
60
fa
CE
Conformity with
standards
3250
39
0.25
120
-25
; Use the device in accordance with its degree of protection.
70
Information on surface quality
0.40
The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.

3.4 Mounting data

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.
Strength class of
screws
For screw clearance, see Chapter 3.1 Product drawing
; Secure the screws against unintentional loosening (e.g. use self-

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)
Min. permitted
ambient temp. for
motor (transport/
storage)
I; If a protective earth is connected by
the customer to the marked PE
connection point.
This component for installation may
have several local protection classes.
This information relates to this
component's basic design.
The final protection class is based on
the component's intended installation and
connection.
EN 60034-1; EN 60204-1; EN 60335-1;
CE
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
8.8
locking screws).
+ 80 °C
- 40 °C

Advertisement

Table of Contents
loading

Table of Contents