HSS Hire 56144 Operating & Safety Manual

Three phase 9kw and 18kw heaters

Advertisement

The heater has a three position switch, '0' for fan
only, '1' for 9Kw heat output, and '2' for 18Kw heat
output.
Note that when the unit is connected to a power
supply and the supply is switched ON, the fan will
run in all three switch positions. Only when set to No
1 or 2 will heat be emitted
Having double-checked that the heater switch is set to the
'0' (fan only position), plug the heater into its power
supply and switch the supply ON.

BASIC TECHNIQUES

Model 1...
Start by setting the switch to position '1', this will
activate the fan without heat. Check that the fan is
running BEFORE you move the switch to position '2'
(the 6.5Kw heat setting).
If the fan fails to run, DISCONNECT THE UNIT AND
SWITCH THE SUPPLY OFF then contact your local HSS
Hire Shop for advice.
Once you have confirmed that the fan is running move
the switch to position '2', this will give an output of
6.5Kw and may prove to be sufficient for your needs.
If setting '2' proves insufficient, move the switch to
position '3'.
Always avoid using more heat than is required and
keep an eye on the room temperature as the heat builds
up.
When you want to switch the unit OFF , turn the
switch to position '1' and leave the unit for at least 5
minutes. In this position, only the fan will run and will
help cool down the heating element before you handle
the unit.
The 'fan only' setting can be used if you wish to
circulate air without heating it.
Model 2...
Check that the fan is running BEFORE you move the
switch to position '1' (the 9Kw heat setting).
If the fan fails to run, DISCONNECT THE UNIT AND
SWITCH THE SUPPLY OFF then contact your local HSS
Hire Shop for advice.
Once you have confirmed that the fan is running move
the switch to position '1', this will give an output of 9Kw
and may prove to be sufficient for your needs.
If setting '1' proves insufficient, move the switch to
position '2'.
Always avoid using more heat than is required and
keep an eye on the room temperature as the heat builds
up.
When you want to switch the unit OFF , turn the
switch to position '0' and leave the unit for at least 5
minutes. In this position, only the fan will run and will
help cool down the heating element before you handle
the unit.
The 'fan only' setting can be used if you wish to
circulate air without heating it.

EQUIPMENT CARE

Never push the equipment beyond its design limits.
If it will not do what you want with reasonable ease and
speed, assume you have the wrong heater for the job.
Contact your local HSS Hire Shop for advice.
Keep the equipment clean - you will find this less of a
chore if you clean it regularly, rather than wait until the end
of the hire period.
When not in use, store the equipment somewhere
clean, dry and safe from thieves.

FINISHING OFF

Set the switch to 'fan only and wait for the unit to
cool down.
Once cool switch the supply OFF and unplug it from
the power supply.
All that remains is to give the unit a final clean up
ready for return, to your local HSS Hire Shop.
...any comments?
If you have any suggestions to enable us to improve
the information within this guide please fax your
comments or write to the Product Manager at the
address below
Fax: 020 8687 5001
©HSS Hire Service Group Ltd 2004 No. 892/02
Group Office: 25 Willow Lane, Mitcham, Surrey CR4 4TS
Web Site: http://www.hss.com
Operating & Safety Guide 892
Three Phase
9KW and
18KW Heaters
Three phase fan type heaters offering two
heat settings and one 'fan only' setting.
Code 56144 / 56145

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 56144 and is the answer not in the manual?

Questions and answers

Summary of Contents for HSS Hire 56144

  • Page 1 All that remains is to give the unit a final clean up SWITCH THE SUPPLY OFF then contact your local HSS ready for return, to your local HSS Hire Shop. Hire Shop for advice. Once you have confirmed that the fan is running move the switch to position ‘2’, this will give an output of...
  • Page 2 RCD (Residual This equipment should be used by an able bodied, Fan Only Current-Operated Device) contact your local HSS Hire competent adult who has read and understood these Shop for advice. instructions. Anyone with either a temporary or permanent If the equipment fails, or if its power supply cable or disability, should seek expert advice before using it.

This manual is also suitable for:

56145

Table of Contents