EXCELL PRECISION CO., LTD
Function setting
Press the
key
Input desired
Parameter code
Press the
key
Display shows the existing
parameter code. Input
new code as required.
Press the
key
Continue to another function setting
or press
Item
Function
AnL- 01
Data type
AnL- 02
Signal output
AnL- 03
Weight in Lo
Current / Voltage
AnL- 04
in Lo
AnL- 05
Weight in Hi
Current / Voltage
AnL- 06
in Hi
040112XX
key to escape
Parameter
0
1
2
0
1
000000 ~ 999999
4.0 mA ~ 20.0 mA
or
0.0 V ~ 10.0 V
000000 ~ 999999
4.0 mA ~ 20.0 mA
or
0.0 V ~ 10.0 V
51
Setting value
Description
As display
Gross
Net
Current output
Voltage output
When the weight reaches the value of
that in AnL-03(the Max. weight is the
max setting value (refer to CSP-04 ),
the current / voltage(refer to AnL-02)
output is changed to that configured in
AnL-04
When the weight reaches the value of
that in AnL-05(the Max. weight is the
max setting value (refer to CSP-04 ),
the current / voltage(refer to AnL-02)
output is changed to that configured in
AnL-06
Increment flashing digit
Decrement flashing digit
Move flashing point left
Move flashing point right
Store data in memory
Exit
Escape
/
Default
0
0
0
4.0
30000
20.0
ZSME400000004