Starting The Generator Using Propane - DuroStar DUAL FUEL DS4850EH User Manual

Table of Contents

Advertisement

STARTING THE GENERATOR (CONTINUED)

Starting the Generator Using Propane

1.
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
2.
The gas valve is located above the recoil start on the
bottom of the fuel tank. Rotate the valve counter clockwise
to the horizontal position to stop the flow of gasoline to the
carburetor.
3.
The propane inlet is located on the far right side of the front
panel. Ensure the propane hose is securely connected to
the inlet.
4.
Screw the ACME nut connection on the propane hose to
your propane tank and turn the tank on.
28
Turn breaker off
Turn gas valve off
Connect propane hose
Connect propane tank
5.
Adjust choke
The choke lever is located above the air filter to the right of
the recoil start. Slide the lever to the right to open the choke
and increase air into the carburetor for normal running.
6.
Start the generator
The engine switch is located on the left side of the front
power panel. Press the switch up to the "START" Position.
7.
Allow switch return to RUN
When the engine starts, allow the engine switch to return to
the "RUN" position.
8.
Turn breaker on / connect
The breaker is located on the right side of the front power
panel. Flip the breaker up to allow power to flow to the
receptacles. Connect your devices to the receptacles on the
front panel. Start with the largest loads first.
29

Advertisement

Table of Contents
loading

Table of Contents