Kinetik Wellbeing WBP3 Instruction Manual

Kinetik Wellbeing WBP3 Instruction Manual

Wrist blood pressure monitor

Advertisement

Manufactured by:
Harvard Medical Devices Ltd. HK
Company: Harvard Medical Devices Ltd. HK
Address: 1002, Railway Plaza, TST, HK
Authorized European Representative:
Company: Share Info Consultant Service LLC Repräsentanzbüro
Address: Heerdter Lohweg 83, 40549 Düsseldorf
Made in China
0197
Kinetik WBP3 UK IB 20210723
wrist blood pressure monitor
.
To use the monitor correctly and safely, please read the manual thoroughly.
.
Please keep this manual well in order to reference in future.
Instruction Manual
By cmlam at 2:36 pm, Jul 29, 2021
WBP3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WBP3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kinetik Wellbeing WBP3

  • Page 1 Address: Heerdter Lohweg 83, 40549 Düsseldorf Made in China To use the monitor correctly and safely, please read the manual thoroughly. Please keep this manual well in order to reference in future. Instruction Manual WBP3 0197 Kinetik WBP3 UK IB 20210723...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ....................General Description Indications for Use Contraindications...
  • Page 3: Introduction

    The design provides you with two years of reliable such as cardiac pacemakers, defibrillators. service. Readings taken by the WBP3 are equivalent to those obtained by a trained Measurement Principle observer using the cu and stethoscope auscultation method.
  • Page 4: Safety Information

    INTRODUCTION INTRODUCTION Safety Information CAUTION The signs below might be in the user manual, labeling or other component. * This device is intended for adult use in homes only. They are the requirement of standard and using. * The device is not suitable for use on neonatal patients, pregnant women,patients with implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial fibrillation, Read the instructions (actual symbol Symbol for “TYPE BF APPLIED...
  • Page 5 INTRODUCTION INTRODUCTION CAUTION CAUTION * The patient can measure data and change batteries under normal circumstances and maintain the device *On the rare occasion of a fault causing the cuff to remain fully inflated during measurement, open the cuff and its accessories according to the user manual. immediately.
  • Page 6: Lcd Display Symbol

    INTRODUCTION INTRODUCTION CAUTION CAUTION * Cleaning :Dust environment may affect the performance of the unit. Please use the soft cloth to clean the * When using this device, please pay attention to the following situation which may interrupt blood flow and whole unit before and after use.
  • Page 7: Monitor Components

    INTRODUCTION INTRODUCTION Monitor Components SYMBOL DESCRIPTION EXPLANATION Measurement unit of the blood pressure (1kPa=7.5mmHg) Measurement unit the blood pressure mmHg (1mmHg=0.133kPa) Blood pressure monitor is detecting an Irregular heartbeat irregular heartbeat during measurement. TIME SYSTOLIC Current time Month/Day,Hour/Minute GRADE PRESSURE The average value of latest 3 groups blood pressure Average value value.
  • Page 8: List

    • Replace the cover. The typical service life of the new and unused batteries is 60 measurements for the operation time is 60s. BATTERY COMPARTMENT List 1) Blood Pressure Monitor WBP3 2) 2×AAA alkaline batteries (Not Included) 3) User manual...
  • Page 9: Setting Date, Time, Positioning Symbol And Measurement Unit

    BEFORE YOU START BEFORE YOU START Setting Date, Time, Positioning Symbol and Replace the batteries whenever the below happen Measurement Unit It is important to set the clock before using your blood shows pressure monitor, so that a time stamp can be assigned to The display is dim.
  • Page 10 BEFORE YOU START BEFORE YOU START 4. Repeat step 2 and 3 to confirm [MONTH] and [DAY]. Notes: 1. During the process of setting, you can press “ START/STOP ” button to stop setting at any time. 2. If there is no operation during the process of setting, it will turn o . Press “...
  • Page 11 BEFORE YOU START BEFORE YOU START Repeat step 2 and 3 to confirm [Positioning symbol] on or o . 8. After confirming the meausrement unit, the LCD will display “donE”, then display all the settings you have done one by one and then the monitor will turn o .
  • Page 12: Select The User Id

    BEFORE YOU START BEFORE YOU START Select the User ID After confirming the user ID, the LCD will display “User ID+donE” and then turn o . Then you can start your measurement now. Before you start the measurement, please select the desired user ID first. When the blood pressure monitor is o , press and hold “...
  • Page 13: Measurement

    MEASUREMENT MEASUREMENT Tie the Cu Start the Measurement When the monitor is o , press “ START/STOP ” button to turn on the monitor, Remove all accessories (watch, bracelet, etc) from your wrist. If your physician has diagnosed you with poor circulation in your wrist, use the other one.
  • Page 14 MEASUREMENT MEASUREMENT 2. Press “ START/STOP ” button to power o , otherwise it will turn o within 1 minute. Tips: 1. There are two users in total. Each user has 60 records. 2. You can press “START/STOP ” button to stop measuring during the process of the measurement at any time.
  • Page 15: Data Management

    INFORMATION FOR USER DATA MANAGEMENT DATA MANAGEMENT Recall the Records If you want to check the other user’s measurement records, please press When the monitor is o , press “ MEM ” START/STOP “ ” button to turn o the blood button to show the average value of the pressure monitor.
  • Page 16 DATA MANAGEMENT DATA MANAGEMENT Delete the Records If there is no record, when you press “ MEM ” button to check the record, the display will show. If you did not get the correct measurement, you can delete all the results for the selected user by following steps. (Take user 1 for example.) In the memory mode, hold pressing “...
  • Page 17: Tips For Measurement

    INFORMATION FOR USER INFORMATION FOR USER Maintenance Tips for Measurement To obtain the best performance, please follow the instructions below. Measurements may be inaccurate if taken in the following circumstances. Within 1 hour Immediate measurement Avoid intense shaking and collision. Put in a dry place and Avoid touching water, Within 20 minutes...
  • Page 18: About Blood Pressure

    ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure? Level When ventricles contract and pump blood out of the heart, blood pressure reaches its maximum value, Blood Optimal Normal Mild Moderate Severe High-normal Pressure (mm Hg) the highest pressure in the cycle is known as systolic pressure.
  • Page 19: Why Does My Blood Pressure Fluctuate Throughout The Day

    ABOUT BLOOD PRESSURE TROUBLESHOOTING Why does my blood pressure fluctuate throughout the day? This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor. If the products not operating as you 1.
  • Page 20: Specifications

    TROUBLESHOOTING SPECIFICATIONS PROBLEM SYMPTOM CHECK THIS REMEDY Power supply Battery powered mode: 2*AAA batteries (3V DC) Display mode Error Digital LCD V.A. 45mm x 33mm EExx,shows on A calibration error occurred. Retake the measurement.If the problem the display. (XX can be some digital persists,contact the retailer or our customer message Measurement mode...
  • Page 21: Manufacturer Information

    SPECIFICATIONS MANUFACTURER INFORMATION Manufacturer Information Mode of operation Manufactured by: Harvard Medical Devices Ltd. HK Continuous operation Company: Harvard Medical Devices Ltd. HK Degree of protection Address: 1002, Railway Plaza, TST, HK Type BF applied part Device Classification Internally Powered ME Equipment Authorized European Representative: Company: Share Info Consultant Service LLC Repräsentanzbüro IP22: The first number 2: Protected against solid foreign...
  • Page 22: Complied Standards List

    EMC GUIDANCE COMPLIED STANDARDS LIST COMPLIED STANDARDS LIST Complied Standards List EN 1060-3:1997+A2:2009 Non-invasive sphygmomanometers - Part 3: Supplementary requirements for electro-mechanical blood pressure EN ISO 14971:2012 Medical devices - Application of risk management to Risk management measuring systems medical devices IEC 80601-2-30:2009+A1:2013 Medical electrical equipment- Part 2-30: Particular requirements for the basic safety and essential EN ISO 15223-1:2016 Medical devices.
  • Page 23: Emc Guidance

    EMC GUIDANCE EMC GUIDANCE Table 1 EMC Guidance Guidance and manufacturer’s declaration – electromagnetic emissions 1) This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
  • Page 24 EMC GUIDANCE EMC GUIDANCE Table 2 Guidance and manufacturer’s declaration – electromagnetic immunity Voltage dips, 0% U ; 0.5 cycle 0% U ; 0.5 cycle Mains power quality should be short interruptions At 0°, 45°, 90°, 135°, At 0°, 45°, 90°, 135°, that of a typical commercial or and voltage 180°, 225°, 270°...
  • Page 25 EMC GUIDANCE EMC GUIDANCE Table 3 Guidance and manufacturer’s declaration – electromagnetic immunity determined by an electromagnetic site The device is intended for use in the electromagnetic environment specified below. The customer survey, should be less or the user of the device should assure that it is used in such an environment. than the compliance level in each frequency range.
  • Page 26 EMC GUIDANCE EMC GUIDANCE Table 4 Table 5 Recommended separation distances between portable and mobile RF Guidance and manufacturer’s declaration - electromagnetic immunity communications equipment and the device. The device is intended for use in an electromagnetic environment in which radiated RF disturbances The device is intended for use in the electromagnetic environment specified below.
  • Page 27 EMC GUIDANCE 1720 1700- GSM 1800; Pulse CDMA 1900; modulation b) 1990 GSM 1900; 217Hz 1845 DECT; LTE Band 1, 3, 1970 4,25; UMTS Pulse Bluetooth, 2450 2400- modulation b) WLAN, 2570 217 Hz 802.11 b/g/n, RFID 2450, LTE Band 7 5240 5100- WLAN...