6. Electronic Parts
6.1 The Product doesn't operate at all
Turn off the main power and
wait for 10 seconds.
Turn on the main power again.
A "Beeping" sound is made
from the indoor unit
No
Check the voltage of power supply (AC 220 V / AC 240 V, 50 Hz) and check
for the following :
* The voltage of main power supply.
* The voltage applied to the unit.
* The connecting method of Indoor/Outdoor connecting cable (each color)
* The PCB Assembly (Fuse, Noise Filter, Power Module, Bridge Diode, etc.)
The operation check of the Indoor PCB Assembly
Procedure
1) The input voltage of power mod-
ule.
2) The output voltage of power mod-
ule.
4) IC04D(7805)
5) IC01A(KIA7036)
Primarily, the operating condition of
Micom is O.K.
Yes
* Check, Remote controller & Receiver.
* Check CN-DISP1, CN-DISP2
indoor PCB
Specification
1) AC 230 V ± 30 V
: Check the rated voltage
2) 12 V ± 3 V
4) DC 5 V
5) The voltage of micom pin 19
: DC 4.5 V↑
- 58 -
Part 4 Trouble Shooting
of
Remedy
1) Check the power outlet.
2) Replace
PCB Assembly
4) Replace PCB Assembly
5) Replace PCB Assembly
Copyright © 2019 - 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.