■ PFCM Point
Division
4kW
Sequence of
Measurement Measurement
1
2
❈ C : Collector / E : Emitter
2kW
3kW
IGBT
IGBT
FRD
< IGBT >
Normal
Standards
C – E
0.3 V~0.5 V
C – E
0.3 V~0.5 V
PFCM Point
< FRD >
Sequence of
Measurement Measurement
1
A – C
2
A – C
❈ A : Anode / C : Cathode
- 104 -
Copyright © 2019 - 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.
Part 4 Trouble Shooting
0.3 ~ 0.5 V
Vdc
Black
Red
Normal
Standards
0.3 V~0.5 V
0.3 V~0.5 V